ASME A112.18.6-2017/CSA B125.6-17
Current
The latest, up-to-date edition.
Flexible water connectors
Hardcopy , PDF
English
01-01-2017
Preface
1 Scope
2 Reference publications
3 Definitions and abbreviations
4 General requirements
5 Performance requirements and test methods
6 Markings
Annex A (informative) - Exposure to aqueous chloramine
Annex B (informative) - Unit conversion and rounding criteria
Contains flexible water connectors for use in water supply systems under: a) continuous pressure in accessible locations; and b) intermittent pressure in recreational vehicles only.
DevelopmentNote |
Also numbered as ASME A112.18.6. Jointly published by ASME and CSA. (08/2017) This standard was just updated in our system however it was originally released on 08-2017
|
DocumentType |
Standard
|
ISBN |
978-1-4883-0468-2
|
Pages |
0
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Supersedes |
Preface This is the second edition of ASME A112.18.6/CSA B125.6, Flexible water connectors. It supersedes the previous edition published in 2009. The following changes appear in this edition: a) updated reference to the latest edition of NSF 61; b) revised working temperatures; c) new low lead requirements; d) updated fill valve thread requirements; and e) updated ice maker pressure drop requirements. Scope 1.1 This Standard covers flexible water connectors for use in water supply systems under a) continuous pressure in accessible locations; and b) intermittent pressure in recreational vehicles only. 1.2 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.3 SI units are the units of record in Canada. In this Standard, the yard/pound units are shown in parentheses. The values stated in each measurement system are equivalent in application; however, each system is to be used independently. Combining values from the two measurement systems can result in non-conformance with this Standard. All references to gallons are to U.S. gallons. For information on the conversion criteria used in this Standard, see Annex B.
CSA B125.5 : 2011 : R2016 | FLEXIBLE WATER CONNECTORS WITH EXCESS FLOW SHUT-OFF DEVICES |
ASME A112.18.1 : 2012 | PLUMBING SUPPLY FITTINGS |
ASME A112.18.1 : 2012 : R2017 | PLUMBING SUPPLY FITTINGS |
B125.3-18 | Plumbing fittings |
ICC IPC CODE & COMMENTARY : 2015 | IPC® Code and Commentary |
ICC IRC CODE AND COMMENTARY VOLUME 2 : 2015 | IRC® Code and Commentary, Volume 2 |
ICC 2012 INTERNATIONAL RESI. CODE : 2012 | INTERNATIONAL RESIDENTIAL CODE FOR ONE- AND TWO-FAMILY DWELLINGS |
ICC 2012 INTERNATIONAL PLUMBING CODE : 2012 | INTERNATIONAL PLUMBING CODE (INCLUDES IPSDC) |
CSA B125.2 : 2015 | PLUMBING WASTE FITTINGS |
CSA B125.1:2012 | PLUMBING SUPPLY FITTINGS |
CSA B125.5 : 2011 | FLEXIBLE WATER CONNECTORS WITH EXCESS FLOW SHUT-OFF DEVICES |
ICC IRC International Residential Code:2021 | 2021 International Residential Code |
ASME A112.19.12:2014(R2024) | Wall Mounted, Pedestal Mounted, Adjustable, Elevating, Tilting, and Pivoting Lavatory, Sink, and Shampoo Bowl Carrier Systems and Drain Waste Systems |
ASME A112.18.2 : 2015 | PLUMBING WASTE FITTINGS |
ASSE 1002-2015/ ASME A112.1002-2015/ CSA B125.12 : 2015 | ANTI-SIPHON FILL VALVES FOR WATER CLOSET TANKS |
CSA B125.12 : 2015 | ANTI-SIPHON FILL VALVES FOR WATER CLOSET TANKS |
NSF 61 : 2016 | DRINKING WATER SYSTEM COMPONENTS - HEALTH EFFECTS |
ASSE 1061 : 2015 | PERFORMANCE REQUIREMENTS FOR PUSH-FIT FITTINGS |
ASTM D 6284 : 2017 : REDLINE | Standard Test Method for Rubber Property—Effect of Aqueous Solutions with Available Chlorine and Chloramine |
ASME A112.19.5 : 2005 | FLUSH VALVES AND SPUDS FOR WATER CLOSETS, URINALS, AND TANKS |
ASME B16.18 : 2001 : R2005 | CAST COPPER ALLOY SOLDER JOINT PRESSURE FITTINGS |
ASME B1.20.1 : 1983(R2006) | PIPE THREADS, GENERAL PURPOSE (INCH) |
ASME B16.22 : 2001 : R2005 | WROUGHT COPPER AND COPPER ALLOY SOLDER-JOINT PRESSURE FITTINGS |
SAE J512 : 1997 | AUTOMOTIVE TUBE FITTINGS |
ISA 75.02 : 1996 | CONTROL VALVE CAPACITY TEST PROCEDURES |
NSF 372 : 2016 | DRINKING WATER SYSTEM COMPONENTS - LEAD CONTENT |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.