• Shopping Cart
    There are no items in your cart

ASTM A 327 : 1991 : R2006

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Methods for Impact Testing of Cast Irons

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Superseded by

ASTM A 327/A327M : 2011

Language(s)

English

Published date

01-02-2006

€59.22
Excluding VAT

CONTAINED IN VOL. 01.02, 2012 Defines the details of apparatus, test specimens and procedures for cast iron, including gray iron, white iron, malleable iron, ductile iron, and austempered ductile iron, but not including chilled rolls or rolls with white iron skins.

Committee
A 04
DocumentType
Test Method
Pages
4
ProductNote
Reconfirmed 2006
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 These test methods for impact testing cover the details of apparatus, test specimens and procedures for cast iron, including gray iron, white iron, malleable iron, ductile iron, and austempered ductile iron, but not including chilled rolls or rolls with white iron skins.

1.2 The values stated in inch-pound units are to be regarded as the standard. A companion standard, A 327M, lists values in SI units.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.3 The Charpy-type impact test shall be employed for testing gray and white irons.

1.4 Either the standard notched or unnotched Charpy impact test shall be employed in testing of malleable or ductile irons. Selection of the type bar is dependent upon the specific material to be evaluated as defined in Section .

1.5 Both types of charpy bars have been designated to characterize the fracture toughness of irons. The unnotched Charpy bar, when tested, will produce substantially higher energy values than the notch bar type. The unnotched bar is therefore specified for testing irons that have low fracture toughness characteristics.