Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Superseded by

ASTM A 884/A884M : 2014

Language(s)

English

Published date

15-05-2012

€67.30
Excluding VAT

Committee
A 01
DocumentType
Standard
Pages
6
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This specification covers plain and deformed steel wire and plain and deformed steel welded wire reinforcement with protective epoxy coating. A Class A minimum coating thickness is required for wire and welded wire reinforcement intended for use in concrete and masonry. A Class B minimum coating thickness is required for wire and welded wire reinforcement intended for use in mechanically stabilized earth applications. A Type 1 coating is a fusion-bonded epoxy coating that has been formulated to be sufficiently flexible to allow bending of the coated wire or welded wire reinforcement. A Type 2 coating is a fusion-bonded epoxy coating that has not been designed to be sufficiently flexible to allow bending of the coated wire or welded wire reinforcement.

Note 1The coating applicator is identified throughout this specification as the manufacturer.

1.2This specification is applicable for orders in either inch-pound units (as Specification A884) or SI units (as Specification A884M).

1.3The values stated in either inch-pound or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other except as specifically noted in Table 1. Combining values from the two systems may result in non-conformance with this specification.

TABLE 1 Best Test Requirements

Wire Size
No.
W or D

Wire Size No.
MW or MD

Mandrel Diameter

Time to
Complete, s
[maximum]

1.4 to 6

9 to 39

Two times the diameter
of the wire
 being tested
(2d)A

15

>6

>39

Four times the
diameter of the
 wire being tested
(4d)A

45

A d = nominal diameter of wire.

1.4This specification does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this specification to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.