ASTM C 1075 : 2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practices for Sampling Uranium-Ore Concentrate
Hardcopy , PDF
08-09-2020
English
01-01-2010
Committee |
C 26
|
DocumentType |
Standard Practice
|
Pages |
10
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 These practices are intended to provide the nuclear industry with procedures for obtaining representative bulk samples from uranium-ore concentrates (UOC) (see Specification C967).
1.2 These practices also provide for obtaining a series of representative secondary samples from the original bulk sample for the determination of moisture and other test purposes, and for the preparation of pulverized analytical samples (see Test Methods C1022).
1.3 These practices consist of a number of alternative procedures for sampling and sample preparation which have been shown to be satisfactory through long experience in the nuclear industry. These procedures are described in the following order.
Stage | Procedure | Section |
Primary Sampling | One-stage falling stream | 4 |
Two-stage falling stream | 5 | |
Auger | 6 | |
Secondary Sampling | Straight-path (reciprocating) | 7 |
Rotating (Vezin) | 8, 9 | |
Sample Preparation | 10 | |
Concurrent-drying | 11-13 | |
Natural moisture | 14-16 | |
Calcination | 17, 18 | |
Sample Packaging | 19 | |
Wax sealing | 20 | |
Vacuum sealing | 21 |
1.3.1 The primary and secondary sampling stages can be organized in the following way:
1.3.2 It is possible to combine the various elements of these stages in different ways to give satisfactory results depending on the agreed requirements of the contracting parties. For a given stage, however, each procedure must be regarded as a whole. It is highly inadvisable to mix elements belonging to different procedures.
1.4 These procedures do not include requirements for health, safety, and accountability. The observance of these practices does not relieve the user of the obligation to be aware of and to conform to all applicable international, federal, state, and local regulations pertaining to processing, shipping, or using uranium-ore concentrates. (Guidance is provided in CFR 10, Chapter 1.)
1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.6 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM C 967 : 2013 | Standard Specification for Uranium Ore Concentrate |
ASTM C 1843 : 2016 | Standard Test Method for Determining Moisture Content in Uranium-Ore Concentrate |
ASTM C 1845 : 2016 | Standard Practice for The Separation of Lanthanide Elements from Uranium Matrices Using High Pressure Ion Chromatography (HPIC) for Isotopic Analyses by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.