Standard Specification for Asbestos-Cement Products Other Than Fill For Cooling Towers (Withdrawn 2019)

Available format(s)

Hardcopy , PDF

Withdrawn date

11-11-2019

Language(s)

English

Published date

01-12-2014

€59.22
Excluding VAT

CONTAINED IN VOL. 04.05, 2015 Defines drift eliminators or demisters, louvers, partitioning and casing panels.

Committee
C 17
DocumentType
Standard
Pages
3
ProductNote
Reconfirmed 2014
PublisherName
American Society for Testing and Materials
Status
Withdrawn
Supersedes

1.1This specification covers drift eliminators or demisters, louvers, partitioning and casing panels.

Note 1:Asbestos-cement pipes are covered in Specifications C296 and C428; and asbestos-cement heat exchange fill products are covered in Specification C1082 for flat fill and Specification C1081 for corrugated fill.

1.2The following classes of products are covered:

Paragraph

Classifications

Drift eliminators or demisters

4.1

Classes 1, 2 and 3

Louvers

4.2

Classes 1 and 2

Casing panels

4.3

Classes 1 and 2

Asbestos-cement pressure pipes

4.4

Classes 100, 150, and 200

Asbestos-cement nonpressure or gravity drainage pipes

4.5

Classes 1500, 2400, 3300, 4000, and 5000

1.2.1Products cured at atmospheric pressure or by autoclaving are covered.

1.3The values stated in the SI system are to be regarded as the standard. The inch-pound units in parentheses are provided for information only.

1.4Warning—Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysoltile asbestos, refer to “Safe Use of Chrysotile Asbestos: A Manual on Preventive and Control Measures.”2

1.5The following safety hazards caveat pertains only to the test method portion of this specification (Section 5): This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use. For a specific safety hazard, see .

ASTM C 1081 : 1998 : R2014 Standard Specification for Asbestos-Cement Corrugated Fill For Use in Cooling Towers (Withdrawn 2019)
ASTM D 5952 : 2008 : R2015 Standard Guide for the Inspection of Water Systems for Legionella and the Investigation of Possible Outbreaks of Legionellosis (Legionnaires' Disease or Pontiac Fever) (Withdrawn 2024)

ASTM D 2946 : 2001 Standard Terminology for Asbestos and Asbestos-Cement Products
ASTM C 1081 : 1998 : R2003 : EDT 1 Standard Specification for Asbestos-Cement Corrugated Fill For Use in Cooling Towers
ASTM C 1081 : 1998 : R2003 Standard Specification for Asbestos-Cement Corrugated Fill For Use in Cooling Towers
ASTM C 1082 : 1998 : R2014 Standard Specification for Asbestos-Cement Flat Sheet for Cooling Tower Fill (Withdrawn 2019)
ASTM D 2946 : 2001 : R2005 Standard Terminology for Asbestos and Asbestos-Cement Products
ASTM D 2946 : 2001 : R2010 Standard Terminology for Asbestos and Asbestos-Cement Products
ASTM D 2946 : 1998 Standard Terminology for Asbestos and Asbestos-Cement Products
ASTM C 1081 : 1998 Standard Specification for Asbestos-Cement Corrugated Fill For Use in Cooling Towers
ASTM C 1082 : 1998 : R2003 : EDT 1 Standard Specification for Asbestos-Cement Flat Sheet for Cooling Tower Fill
ASTM C 1081 : 1998 : R2014 Standard Specification for Asbestos-Cement Corrugated Fill For Use in Cooling Towers (Withdrawn 2019)
ASTM C 1082 : 1998 Standard Specification for Asbestos-Cement Flat Sheet for Cooling Tower Fill
ASTM C 1081 : 1998 : R2008 Standard Specification for Asbestos-Cement Corrugated Fill For Use in Cooling Towers
ASTM C 1082 : 1998 : R2008 Standard Specification for Asbestos-Cement Flat Sheet for Cooling Tower Fill
ASTM D 2946 : 2001 : R2018 Standard Terminology for Asbestos and Asbestos–Cement Products (Withdrawn 2022)
ASTM C 1082 : 1998 : R2003 Standard Specification for Asbestos-Cement Flat Sheet for Cooling Tower Fill

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.