Standard Specification for Asbestos-Cement Corrugated Fill For Use in Cooling Towers (Withdrawn 2019)
Hardcopy , PDF
11-11-2019
English
01-12-2014
CONTAINED IN VOL. 04.05, 2015 Outlines splash bar and corrugated sheet type asbestos-cement products used as cooling tower fill.
Committee |
C 17
|
DocumentType |
Standard
|
Pages |
3
|
ProductNote |
Reconfirmed 2014
|
PublisherName |
American Society for Testing and Materials
|
Status |
Withdrawn
|
Supersedes |
1.1This specification covers splash bar and corrugated sheet type asbestos-cement products used as cooling tower fill.
1.2Drift eliminators or demisters, louvers, partitioning and casing panels are covered in Specifications C1080. Asbestos-cement pipes are covered in Specification C296 and Specifications C428. Asbestos-cement flat sheet fill (heat exchange surfaces) are specified in Specification C1082.
1.3The values stated in the SI system are to be regarded as the standard. The inch-pound units in parentheses are for information only.
1.4Warning—Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysoltile asbestos, refer to “Safe Use of Chrysotile Asbestos: A Manual on Preventive and Control Measures.”2
1.5The following precautionary caveat pertains only to the Test Method portion, Section 8, of this Specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See 1.4 for a specific safety hazard.
ASTM C 1080 : 1998 : R2014 | Standard Specification for Asbestos-Cement Products Other Than Fill For Cooling Towers (Withdrawn 2019) |
ASTM C 1082 : 1998 : R2014 | Standard Specification for Asbestos-Cement Flat Sheet for Cooling Tower Fill (Withdrawn 2019) |
ASTM C 1096 : 1991 : R1999 | Standard Test Method for Determination of Wood Fiber in Asbestos Cement |
ASTM D 2946 : 2001 | Standard Terminology for Asbestos and Asbestos-Cement Products |
ASTM C 1080 : 1998 : R2003 | Standard Specification for Asbestos-Cement Products Other Than Fill For Cooling Towers |
ASTM C 1082 : 1998 : R2014 | Standard Specification for Asbestos-Cement Flat Sheet for Cooling Tower Fill (Withdrawn 2019) |
ASTM D 2946 : 2001 : R2005 | Standard Terminology for Asbestos and Asbestos-Cement Products |
ASTM D 2946 : 2001 : R2010 | Standard Terminology for Asbestos and Asbestos-Cement Products |
ASTM C 1080 : 1998 : R2003 : EDT 1 | Standard Specification for Asbestos-Cement Products Other Than Fill For Cooling Towers |
ASTM C 1080 : 1998 : R2014 | Standard Specification for Asbestos-Cement Products Other Than Fill For Cooling Towers (Withdrawn 2019) |
ASTM D 2946 : 1998 | Standard Terminology for Asbestos and Asbestos-Cement Products |
ASTM C 1096 : 1991 : R2004 | Standard Test Method for Determination of Wood Fiber in Asbestos Cement |
ASTM C 1082 : 1998 : R2003 : EDT 1 | Standard Specification for Asbestos-Cement Flat Sheet for Cooling Tower Fill |
ASTM C 1082 : 1998 | Standard Specification for Asbestos-Cement Flat Sheet for Cooling Tower Fill |
ASTM C 1096 : 1991 : R2004 : EDT 1 | Standard Test Method for Determination of Wood Fiber in Asbestos Cement |
ASTM C 1082 : 1998 : R2008 | Standard Specification for Asbestos-Cement Flat Sheet for Cooling Tower Fill |
ASTM D 2946 : 2001 : R2018 | Standard Terminology for Asbestos and Asbestos–Cement Products (Withdrawn 2022) |
ASTM C 1080 : 1998 | Standard Specification for Asbestos-Cement Products Other Than Fill For Cooling Towers |
ASTM C 1082 : 1998 : R2003 | Standard Specification for Asbestos-Cement Flat Sheet for Cooling Tower Fill |
ASTM C 1080 : 1998 : R2008 | Standard Specification for Asbestos-Cement Products Other Than Fill For Cooling Towers |
ASTM C 1096 : 2007 | Standard Test Method for Determination of Wood Fiber in Asbestos Cement |