CONTAINED IN VOL. 04.06, 2006 Specifies the criteria to be considered in specifying removable insulation covers for surfaces operating in air at temperatures above ambient.

Committee
C 16
DocumentType
Guide
Pages
4
ProductNote
Reconfirmed 2001
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This guide recommends the criteria to be considered in specifying removable insulation covers for surfaces operating in air at temperatures above ambient.

1.2 A removable insulation cover is fabricated from a fibrous insulation material encased in a tailored fabric or wire mesh enclosure, or both. The fabric seams are typically held together with thread, metal rings, or staples, or combination thereof. These covers must be designed and fabricated to allow a close fit with tight joints over piping, elbows, flanges, valves, and tanks. They are intended to be easily removed and replaced to allow for periodic access to the surfaces they cover.

1.3 In addition to thermal performance, there are other performance requirements of removable covers. These may include, but are not limited to:

1.3.1 Temperature exposure,
1.3.2 Chemical and weather exposure,
1.3.3 Acoustical, and
1.3.4 Fire endurance.

1.4 The materials from which the cover is made may include, but are not limited to:

1.4.1 Insulation media,
1.4.2 Fabric, metal mesh enclosure, or foil enclosure,
1.4.3 Seam materials (thread, metal hooks, etc.), and
1.4.4 Attachment system (hook and loop attachment, straps, wire, etc.).

1.5 The shape, size, and physical design of the cover varies depending on the object to be covered. The cover may consist of more than one piece. Pipes, valves, pumps, and flanges are typical objects to be covered. In many cases, on-site measurements need to be made to ensure an acceptable fit.

1.6 The values stated in SI units shall be regarded as the standard. The values given in parentheses are provided for information only.

1.7 This guide does not intend to establish the criteria required in the design of the equipment over which removable insulation covers are used, nor does this guide establish or recommend the applicability of removable insulation covers over all surfaces.

1.8 It is the responsibility of the user, user's agent, or both, to determine applicability of this guide to their specific application and to inform the equipment designer of the intent to insulate so that appropriate design criteria can be established.

1.9 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.10 This standard should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use.

ASTM C 553 : 2013 : REDLINE Standard Specification for Mineral Fiber Blanket Thermal Insulation for Commercial and Industrial Applications
ASTM C 423 : 2017 : REDLINE Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method
ASTM D 1894 : 2014 : REDLINE Standard Test Method for Static and Kinetic Coefficients of Friction of Plastic Film and Sheeting
NFPA 701 : 2015 FIRE TESTS FOR FLAME PROPAGATION OF TEXTILES AND FILMS
ASTM D 2176 : 2016 Standard Test Method for Folding Endurance of Paper and Plastics Film by the M.I.T. Tester
ASTM C 592 : 2016 : REDLINE Standard Specification for Mineral Fiber Blanket Insulation and Blanket-Type Pipe Insulation (Metal-Mesh Covered) (Industrial Type)
ASTM G 26 : 1996 Practice for Operating Light-Exposure Apparatus (Xenon-Arc Type) With and Without Water for Exposure of Nonmetallic Materials (Withdrawn 2000)
ASTM D 1117 : 2001 Standard Guide for Evaluating Nonwoven Fabrics (Withdrawn 2009)
ASTM C 1393 : 2014-02 SPECIFICATION FOR PERPENDICULARLY ORIENTED MINERAL FIBER ROLL AND SHEET THERMAL INSULATION FOR PIPES AND TANKS
ASTM C 547 : 2017 : REDLINE Standard Specification for Mineral Fiber Pipe Insulation
ASTM D 471 : 2016-02 TEST METHOD FOR RUBBER PROPERTY - EFFECT OF LIQUIDS
ASTM C 795 : 2008 Standard Specification for Thermal Insulation for Use in Contact with Austenitic Stainless Steel
ASTM C 1682 : 2017 : REDLINE Standard Guide for Characterization of Spent Nuclear Fuel in Support of Interim Storage, Transportation and Geologic Repository Disposal

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.