ASTM C 1153 : 2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Location of Wet Insulation in Roofing Systems Using Infrared Imaging
Hardcopy , PDF
21-10-2023
English
01-09-2010
CONTAINED IN VOL. 04.06, 2015 Pertains to techniques that employ infrared imaging at night to determine the location of wet insulation in roofing systems that have insulation above the deck in contact with the waterproofing.
Committee |
C 16
|
DocumentType |
Standard Practice
|
Pages |
6
|
ProductNote |
Reconfirmed 2010
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 This practice applies to techniques that employ infrared imaging at night to determine the location of wet insulation in roofing systems that have insulation above the deck in contact with the waterproofing. This practice includes ground-based and aerial inspections. (Warning—Extreme caution shall be taken when accessing or walking on roof surfaces and when operating aircraft at low altitudes, especially at night.) (Warning—It is a good safety practice for at least two people to be present on the roof surface at all times when ground-based inspections are being conducted.)
1.2 This practice addresses criteria for infrared equipment such as minimum resolvable temperature difference, spectral range, instantaneous field of view, and field of view.
1.3 This practice addresses meteorological conditions under which infrared inspections shall be performed.
1.4 This practice addresses the effect of roof construction, material differences, and roof conditions on infrared inspections.
1.5 This practice addresses operating procedures, operator qualifications, and operating practices.
1.6 This practice also addresses verification of infrared data using invasive test methods.
1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 1.1.
ASTM C 1046 : 1995 : R2013 | Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components |
ASTM E 2813 : 2018 | Standard Practice for Building Enclosure Commissioning |
ASTM D 7053/D7053M : 2017 | Standard Guide for Determining and Evaluating Causes of Water Leakage of Low-Sloped Roofs |
ASTM C 1155 : 1995 : R2013 | Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data |
ASHRAE 101 : 1981 | APPLICATION OF INFRARED SENSING DEVICES TO THE ASSESSMENT OF BUILDING HEAT LOSS CHARACTERISTICS |
ASTM C 168 : 2017-06 | TERMINOLOGY RELATING TO THERMAL INSULATION |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.