• Shopping Cart
    There are no items in your cart

ASTM C 1153 : 2010 : R2015

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Location of Wet Insulation in Roofing Systems Using Infrared Imaging

Available format(s)

Hardcopy , PDF

Superseded date

20-10-2023

Superseded by

ASTM C 1153 : 2023

Language(s)

English

Published date

23-10-2015

€67.30
Excluding VAT

CONTAINED IN VOL. 04.06, 2015 Pertains to techniques that employ infrared imaging at night to determine the location of wet insulation in roofing systems that have insulation above the deck in contact with the waterproofing.

Committee
C 16
DocumentType
Standard Practice
Pages
6
ProductNote
Reconfirmed 2015
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This practice applies to techniques that employ infrared imaging at night to determine the location of wet insulation in roofing systems that have insulation above the deck in contact with the waterproofing. This practice includes ground-based and aerial inspections. (Warning—Extreme caution shall be taken when accessing or walking on roof surfaces and when operating aircraft at low altitudes, especially at night.) (Warning—It is a good safety practice for at least two people to be present on the roof surface at all times when ground-based inspections are being conducted.)

1.2This practice addresses criteria for infrared equipment such as minimum resolvable temperature difference, spectral range, instantaneous field of view, and field of view.

1.3This practice addresses meteorological conditions under which infrared inspections shall be performed.

1.4This practice addresses the effect of roof construction, material differences, and roof conditions on infrared inspections.

1.5This practice addresses operating procedures, operator qualifications, and operating practices.

1.6This practice also addresses verification of infrared data using invasive test methods.

1.7The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 1.1.

ASTM C 1155 : 1995 : R2021 Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data
ASTM C 1046 : 1995 : R2021 Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components
ASTM D 7053/D7053M : 2017 Standard Guide for Determining and Evaluating Causes of Water Leakage of Low-Sloped Roofs
ASTM C 1155 : 1995 : R2013 Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data
ASTM E 2813 : 2018 Standard Practice for Building Enclosure Commissioning
ASTM C 1046 : 1995 : R2013 Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components

ASTM D 1079 : 2018 : EDT 1 Standard Terminology Relating to Roofing and Waterproofing
ASTM D 1079 : 2008 : REV A Standard Terminology Relating to Roofing and Waterproofing
ASTM E 1213 : 2014 Standard Practice for Minimum Resolvable Temperature Difference for Thermal Imaging Systems
ASTM C 168 : 2019 Standard Terminology Relating to Thermal Insulation
ASTM E 1213 : 1997 : R2002 Standard Test Method for Minimum Resolvable Temperature Difference for Thermal Imaging Systems
ASTM D 1079 : 2016 Standard Terminology Relating to Roofing and Waterproofing
ASTM D 1079 : 2006 Terminology Relating to Roofing and Waterproofing
ASHRAE 101 : 1981 APPLICATION OF INFRARED SENSING DEVICES TO THE ASSESSMENT OF BUILDING HEAT LOSS CHARACTERISTICS
ASTM E 1213 : 2014 : R2022 Standard Practice for Minimum Resolvable Temperature Difference for Thermal Imaging Systems
ASTM D 1079 : 2020 Standard Terminology Relating to Roofing and Waterproofing
ASTM D 1079 : 2013 Standard Terminology Relating to Roofing and Waterproofing
ASTM D 1079 : 2007 : REV A Terminology Relating to Roofing and Waterproofing
ASTM D 1079 : 2010 Standard Terminology Relating to Roofing and Waterproofing
ASTM D 1079 : 2018 Standard Terminology Relating to Roofing and Waterproofing
ASTM D 1079 : 2005 : REV A Terminology Relating to Roofing and Waterproofing
ASTM E 1213 : 1997 Standard Test Method for Minimum Resolvable Temperature Difference for Thermal Imaging Systems
ASTM D 1079 : 2002 Standard Terminology Relating to Roofing, Waterproofing, and Bituminous Materials
ASTM D 1079 : 2001 Standard Terminology Relating to Roofing, Waterproofing, and Bituminous Materials
ASTM E 1213 : 2014 : R2018 Standard Practice for Minimum Resolvable Temperature Difference for Thermal Imaging Systems
ASTM D 1079 : 2000 : REV A Standard Terminology Relating to Roofing, Waterproofing, and Bituminous Materials
ASTM C 168 : 2022 Standard Terminology Relating to Thermal Insulation
ASTM D 1079 : 2013 : EDT 1 Standard Terminology Relating to Roofing and Waterproofing
ASTM E 1213 : 1997 : R2009 Standard Test Method for Minimum Resolvable Temperature Difference for Thermal Imaging Systems
ASTM D 1079 : 2009 Standard Terminology Relating to Roofing and Waterproofing
ASTM C 168 : 2017-06 TERMINOLOGY RELATING TO THERMAL INSULATION

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.