ASTM C 1239 : 2013 : R2024 : EDT 1

Current

Current

The latest, up-to-date edition.

Standard Practice for Reporting Uniaxial Strength Data and Estimating Weibull Distribution Parameters for Advanced Ceramics

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-09-2024

€61.92
Excluding VAT

Committee
C 28
DocumentType
Standard Practice
Pages
18
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

1.1This practice covers the evaluation and reporting of uniaxial strength data and the estimation of Weibull probability distribution parameters for advanced ceramics that fail in a brittle fashion (see Fig. 1). The estimated Weibull distribution parameters are used for statistical comparison of the relative quality of two or more test data sets and for the prediction of the probability of failure (or, alternatively, the fracture strength) for a structure of interest. In addition, this practice encourages the integration of mechanical property data and fractographic analysis.

1.2The failure strength of advanced ceramics is treated as a continuous random variable determined by the flaw population. Typically, a number of test specimens with well-defined geometry are failed under isothermal, well-defined displacement and/or force-application conditions. The force at which each test specimen fails is recorded. The resulting failure stress data are used to obtain Weibull parameter estimates associated with the underlying flaw population distribution.

1.3This practice is restricted to the assumption that the distribution underlying the failure strengths is the two-parameter Weibull distribution with size scaling. Furthermore, this practice is restricted to test specimens (tensile, flexural, pressurized ring, etc.) that are primarily subjected to uniaxial stress states. The practice also assumes that the flaw population is stable with time and that no slow crack growth is occurring.

1.4The practice outlines methods to correct for bias errors in the estimated Weibull parameters and to calculate confidence bounds on those estimates from data sets where all failures originate from a single flaw population (that is, a single failure mode). In samples where failures originate from multiple independent flaw populations (for example, competing failure modes), the methods outlined in Section 9 for bias correction and confidence bounds are not applicable.

1.5This practice includes the following:

Section

Scope

1

Referenced Documents

2

Terminology

3

Summary of Practice

4

Significance and Use

5

Interferences

6

Outlying Observations

7

Maximum Likelihood Parameter Estimators for Competing Flaw Distributions

8

Unbiasing Factors and Confidence Bounds

9

Fractography

10

Examples

11

Keywords

12

Computer Algorithm MAXL

Appendix X1

Test Specimens with Unidentified Fracture Origins

Appendix X2

1.6The values stated in SI units are to be regarded as the standard per IEEE/ASTM SI 10.

1.7This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM C 1557 : 2020 Standard Test Method for Tensile Strength and Young's Modulus of Fibers
ASTM C 1674 : 2023 Standard Test Method for Flexural Strength of Advanced Ceramics with Engineered Porosity (Honeycomb Cellular Channels) at Ambient Temperatures
ASTM C 1211 : 2018 : R2023 Standard Test Method for Flexural Strength of Advanced Ceramics at Elevated Temperatures
ASTM C 1869 : 2018 : R2023 Standard Test Method for Open-Hole Tensile Strength of Fiber-Reinforced Advanced Ceramic Composites
ASTM C 1368 : 2018 Standard Test Method for Determination of Slow Crack Growth Parameters of Advanced Ceramics by Constant Stress Rate Strength Testing at Ambient Temperature
ASTM F 2393 : 2012 : R2020 Standard Specification for High-Purity Dense Magnesia Partially Stabilized Zirconia (Mg-PSZ) for Surgical Implant Applications
ASTM C 1819 : 2021 Standard Test Method for Hoop Tensile Strength of Continuous Fiber-Reinforced Advanced Ceramic Composite Tubular Test Specimens at Ambient Temperature Using Elastomeric Inserts
ASTM C 1341 : 2013 : R2023 Standard Test Method for Flexural Properties of Continuous Fiber-Reinforced Advanced Ceramic Composites
ASTM C 1323 : 2022 Standard Test Method for Ultimate Strength of Advanced Ceramics with Diametrally Compressed C-Ring Specimens at Ambient Temperature
ASTM C 1773 : 2021 Standard Test Method for Monotonic Axial Tensile Behavior of Continuous Fiber-Reinforced Advanced Ceramic Tubular Test Specimens at Ambient Temperature
ASTM C 1683 : 2010 : R2024 Standard Practice for Size Scaling of Tensile Strengths Using Weibull Statistics for Advanced Ceramics
ASTM C 1366 : 2019 Standard Test Method for Tensile Strength of Monolithic Advanced Ceramics at Elevated Temperatures
ASTM C 1834 : 2016 : R2024 Standard Test Method for Determination of Slow Crack Growth Parameters of Advanced Ceramics by Constant Stress Flexural Testing (Stress Rupture) at Elevated Temperatures
ASTM C 1684 : 2018 : R2023 Standard Test Method for Flexural Strength of Advanced Ceramics at Ambient Temperature—Cylindrical Rod Strength
ASTM C 1525 : 2018 : R2024 Standard Test Method for Determination of Thermal Shock Resistance for Advanced Ceramics by Water Quenching
ASTM C 1863 : 2018 Standard Test Method for Hoop Tensile Strength of Continuous Fiber-Reinforced Advanced Ceramic Composite Tubular Test Specimens at Ambient Temperature Using Direct Pressurization
ASTM C 1495 : 2016 : R2023 Standard Test Method for Effect of Surface Grinding on Flexure Strength of Advanced Ceramics
ASTM F 603 : 2012 : R2020 Standard Specification for High-Purity Dense Aluminum Oxide for Medical Application
ASTM C 1275 : 2018 Standard Test Method for Monotonic Tensile Behavior of Continuous Fiber-Reinforced Advanced Ceramics with Solid Rectangular Cross-Section Test Specimens at Ambient Temperature
ASTM C 1273 : 2018 : R2024 Standard Test Method for Tensile Strength of Monolithic Advanced Ceramics at Ambient Temperatures
ASTM C 1468 : 2019 : REV A Standard Test Method for Transthickness Tensile Strength of Continuous Fiber-Reinforced Advanced Ceramics at Ambient Temperature
ASTM D 7972 : 2014 : R2020 Standard Test Method for Flexural Strength of Manufactured Carbon and Graphite Articles Using Three-Point Loading at Room Temperature
ASTM C 1783 : 2015 : R2024 Standard Guide for Development of Specifications for Fiber Reinforced Carbon-Carbon Composite Structures for Nuclear Applications
ASTM C 1161 : 2018 : R2023 Standard Test Method for Flexural Strength of Advanced Ceramics at Ambient Temperature
ASTM C 1465 : 2008 : R2019 Standard Test Method for Determination of Slow Crack Growth Parameters of Advanced Ceramics by Constant Stress-Rate Flexural Testing at Elevated Temperatures
ASTM C 1793 : 2015 : R2024 Standard Guide for Development of Specifications for Fiber Reinforced Silicon Carbide-Silicon Carbide Composite Structures for Nuclear Applications
ASTM C 1322 : 2015 : R2024 Standard Practice for Fractography and Characterization of Fracture Origins in Advanced Ceramics
ASTM C 1499 : 2019 : R2024 Standard Test Method for Monotonic Equibiaxial Flexural Strength of Advanced Ceramics at Ambient Temperature
ASTM C 1899 : 2021 Standard Test Method for Flexural Strength of Continuous Fiber-Reinforced Advanced Ceramic Tubular Test Specimens at Ambient Temperature