ASTM C 1270 : 1997
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Detection Sensitivity Mapping of In-Plant Walk-Through Metal Detectors
Hardcopy , PDF
11-11-2014
English
10-12-1997
CONTAINED IN VOL. 12.01, 2015 Defines a procedure for determining the weakest detection path through the portal aperture and the worst-case orthogonal orientation of metallic test objects.
Committee |
C 26
|
DocumentType |
Standard Practice
|
Pages |
9
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 This standard practice covers a procedure for determining the weakest detection path through the portal aperture and the worst-case orthogonal orientation (Note 1) of metallic test objects. It results in detection sensitivity maps, which model the detection zone in terms related to detection sensitivity and identify the weakest detection paths. Detection sensitivity maps support sensitivity adjustment and performance evaluation procedures (see Practice C1269).
Note 1-As used in this practice, orthogonal orientation refers to alignment of the longitudinal axis of a test object along the XYZ axes of the Cartesian coordinate system; is horizontal and across the portal, is vertical, and is in the direction of travel through the portal. Note 2-Unsymmetrical metal objects possessing a primary longitudinal component, such as handguns and knives, usually have one particular orientation that produces the weakest detection signal. The orientation and the path through the detector aperture where the weakest response is produced may not be the same for all test objects, even those with very similar appearance. Note 3-In the case of multiple specified test objects or for test objects that are orientation sensitive, it may be necessary to map each object several times to determine the worst-case test object or orientation, or both.1.2 This practice is one of several developed to assist operators of walk-through metal detectors with meeting the metal detection performance requirements of the responsible regulatory authority.
1.3 This practice is neither intended to set performance levels, nor limit or constrain operational technologies.
1.4 This practice does not address safety or operational issues associated with the use of walk-through metal detectors.
1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
ASTM C 1309 : 1997 : R2012 | Standard Practice for Performance Evaluation of In-Plant Walk-Through Metal Detectors |
ASTM C 1269 : 1997 | Standard Practice for Adjusting the Operational Sensitivity Setting of In-Plant Walk-Through Metal Detectors |
ASTM C 1309 : 1997 : R2003 | Standard Practice for Performance Evaluation of In-Plant Walk-Through Metal Detectors |
ASTM C 1309 : 1997 | Standard Practice for Performance Evaluation of In-Plant Walk-Through Metal Detectors |
ASTM C 1269 : 1997 : R2003 | Standard Practice for Adjusting the Operational Sensitivity Setting of In-Plant Walk-Through Metal Detectors |
ASTM C 1269 : 1997 : R2012 | Standard Practice for Adjusting the Operational Sensitivity Setting of In-Plant Walk-Through Metal Detectors |
ASTM C 1269 : 1997 | Standard Practice for Adjusting the Operational Sensitivity Setting of In-Plant Walk-Through Metal Detectors |
ASTM C 1238 : 1997 | Standard Guide for Installation of Walk-Through Metal Detectors |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.