ASTM C 1270 : 1997 : R2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Detection Sensitivity Mapping of In-Plant Walk-Through Metal Detectors

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

10-12-1997

€67.30
Excluding VAT

CONTAINED IN VOL. 12.01, 2015 Defines a procedure for determining the weakest detection path through the portal aperture and the worst-case orthogonal orientation of metallic test objects.

Committee
C 26
DocumentType
Standard Practice
Pages
8
ProductNote
Reconfirmed 2003
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This standard practice covers a procedure for determining the weakest detection path through the portal aperture and the worst-case orthogonal orientation of metallic test objects. It results in detection sensitivity maps, which model the detection zone in terms related to detection sensitivity and identify the weakest detection paths. Detection sensitivity maps support sensitivity adjustment and performance evaluation procedures (see Practices C1269 and C1309).

Note 1—Unsymmetrical metal objects possessing a primary longitudinal component, such as handguns and knives, usually have one particular orientation that produces the weakest detection signal. The orientation and the path through the detector aperture where the weakest response is produced may not be the same for all test objects, even those with very similar appearance.

Note 2—In the case of multiple specified test objects or for test objects that are orientation sensitive, it may be necessary to map each object several times to determine the worst-case test object or orientation, or both.

1.2 This practice is one of several developed to assist operators of walk-through metal detectors with meeting the metal detection performance requirements of the responsible regulatory authority. (See Appendix X2)

1.3 This practice is neither intended to set performance levels, nor limit or constrain operational technologies.

1.4 This practice does not address safety or operational issues associated with the use of walk-through metal detectors.

1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

ASTM C 1269 : 1997 : R2012 Standard Practice for Adjusting the Operational Sensitivity Setting of In-Plant Walk-Through Metal Detectors
ASTM C 1309 : 1997 : R2012 Standard Practice for Performance Evaluation of In-Plant Walk-Through Metal Detectors

ASTM C 1269 : 1997 Standard Practice for Adjusting the Operational Sensitivity Setting of In-Plant Walk-Through Metal Detectors
ASTM C 1238 : 1997 Standard Guide for Installation of Walk-Through Metal Detectors

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.