ASTM C 1289 : 2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
Hardcopy , PDF
08-07-2015
English
01-05-2015
Committee |
C 16
|
DocumentType |
Standard
|
Pages |
7
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This specification covers the general requirements for faced thermal insulation boards composed of rigid cellular polyisocyanurate surfaced with other materials. The insulation boards are intended for use at temperatures between −40 and 200°F (−40 and 93°C). This specification does not cover cryogenic applications. Consult the manufacturer for specific recommendations and properties in cryogenic conditions. For specific applications, the actual temperature limits shall be agreed upon by the manufacturer and the purchaser.
1.2This standard is intended to apply to rigid cellular polyurethane-modified polyisocyanurate thermal insulation board products that are commercially acceptable as non-structural panels useful in building construction. The term polyisocyanurate encompasses the term polyurethane. For engineering and design purposes, users should follow specific product information provided by board manufacturers regarding physical properties, system design considerations and installation recommendations.
Note 1:See Appendix X1 for guidance on determining wind pressure resistance of panels when required for wall sheathing applications.
1.3The use of thermal insulation materials covered by this specification is typically regulated by building codes, or other agencies that address fire performance. Where required, the fire performance of the material shall be addressed through standard fire test methods established by the appropriate governing documents.
1.4The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
Note 2:For conversion to metric units other than those contained in this standard, refer to IEEE/ASTM SI 10.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D 7793 : 2017 | Standard Specification for Insulated Vinyl Siding |
ASTM C 1558 : 2019 | Standard Guide for Development of Standard Data Records for Computerization of Thermal Transmission Test Data for Thermal Insulation |
ASTM E 2568 : 2017 : REV A | Standard Specification for PB Exterior Insulation and Finish Systems |
ASTM C 1535 : 2005 : R2017 | Standard Practice for Application of Exterior Insulation and Finish Systems Class PI |
ASTM C 728 : 2017 : REV A | Standard Specification for Perlite Thermal Insulation Board |
ASTM C 1696 : 2016 | Standard Guide for Industrial Thermal Insulation Systems |
ASTM C 1303/C1303M : 2019 | Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation |
ASTM D 1079 : 2018 : EDT 1 | Standard Terminology Relating to Roofing and Waterproofing |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.