Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipes and Laterals

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Superseded by

ASTM C 1478 : 2006

Language(s)

English

Published date

10-06-2000

€59.22
Excluding VAT

Committee
C 13
DocumentType
Standard
Pages
3
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems.

1.1.1 These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral.

1.2 The values stated in inch-pound units ae to be regarded as standard. The values given in parentheses are for information only.

Note 1-This specificaton covers the design, and material performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 6 psi (14 ft) without leakage when tested in accordance with Section 7. Infiltration quantities for an installed system are dependent upon many factors other than the connections between storm sewer structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.

1.3 The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific warning statement, see 7.2.4.

ASTM C 1821/C1821M : 2016 Standard Practice for Installation of Underground Circular Precast Concrete Manhole Structures