ASTM C 1478M : 2008 : REV A
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipes, and Laterals (Metric)
Hardcopy , PDF
11-11-2014
English
01-10-2008
CONTAINED IN VOL. 04.05, 2015 Defines the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C 478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems.
Committee |
C 13
|
DocumentType |
Standard
|
Pages |
3
|
ProductNote |
Reconfirmed EV A
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C 478
1.1.1 These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral.
1.2 This specification is the SI companion to C 1478.
Note 1—This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 41 kPa (4.3 m) without leakage when tested in accordance with Section 7. Infiltration quantities for an installed system are dependent upon many factors other than the connections between storm sewer structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use. For a specific warning statement, see 7.2.4.
ASTM C 1821/C1821M : 2016 | Standard Practice for Installation of Underground Circular Precast Concrete Manhole Structures |
ASTM D 1149 : 2016-02 | TEST METHODS FOR RUBBER DETERIORATION - CRACKING IN AN OZONE CONTROLLED ENVIRONMENT |
ASTM A 666 : 2015 : REDLINE | Standard Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar |
ASTM D 543 : 2014 : REDLINE | Standard Practices for Evaluating the Resistance of Plastics to Chemical Reagents |
ASTM C 913 : 2016-07 | SPECIFICATION FOR PRECAST CONCRETE WATER AND WASTEWATER STRUCTURES |
ASTM A 493 : 2016 : REDLINE | Standard Specification for Stainless Steel Wire and Wire Rods for Cold Heading and Cold Forging |
ASTM D 1566 : 2015 : REDLINE | TERMINOLOGY RELATING TO RUBBER |
ASTM D 471 : 2016-02 | TEST METHOD FOR RUBBER PROPERTY - EFFECT OF LIQUIDS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.