ASTM C 1479M : 2016 : REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Standard Practice for Installation of Precast Concrete Sewer, Storm Drain, and Culvert Pipe Using Standard Installations (Metric)
07-01-2021
English
15-10-2016
CONTAINED IN VOL. 04.05, 2016 Specifies the installation of precast concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts.
Committee |
C 13
|
DocumentType |
Redline
|
Pages |
10
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
1.1This practice covers the installation of precast concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts.
1.2This practice is the SI companion to Practice C1479.
1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM C 1479 : 2016 : REDLINE | Standard Practice for Installation of Precast Concrete Sewer, Storm Drain, and Culvert Pipe Using Standard Installations |
ASCE 15 98 : 2000 | STANDARD PRACTICE FOR DIRECT DESIGN OF BURIED PRECAST CONCRETE PIPE USING STANDARD INSTALLATIONS (SIDD) |
ASTM C 1479 : 2016 : REDLINE | Standard Practice for Installation of Precast Concrete Sewer, Storm Drain, and Culvert Pipe Using Standard Installations |
AASHTO T 310 : 2013 | METHOD OF TEST FOR IN-PLACE DENSITY AND MOISTURE CONTENT OF SOIL AND SOIL-AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH) |
ASTM D 698 : 2013-05 | TEST METHODS FOR LABORATORY COMPACTION CHARACTERISTICS OF SOIL USING STANDARD EFFORT (12400 FT-LBF/FT[3] (600 KN-M/M[3])) |
IEEE/ASTM SI_10-2010 | American National Standard for Metric Practice |
ASTM C 1417 : 2015 : REDLINE | SPECIFICATION FOR MANUFACTURE OF REINFORCED CONCRETE SEWER, STORM DRAIN, AND CULVERT PIPE FOR DIRECT DESIGN |
AASHTO T 99 : 2015 | METHOD OF TEST FOR MOISTURE-DENSITY RELATIONS OF SOILS USING A 2.5-KG (5.5-LB) RAMMER AND A 305-MM (12-IN.) DROP |
AASHTO M 145 : 1991 | SPECIFICATION FOR CLASSIFICATION OF SOILS AND SOIL-AGGREGATE MIXTURES FOR HIGHWAY CONSTRUCTION PURPOSES |
AASHTO T 180 : 2015 | METHOD OF TEST FOR MOISTURE-DENSITY RELATIONS OF SOILS USING A 4.54-KG (10-LB) RAMMER AND A 457-MM (18-IN.) DROP |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.