ASTM C 1487 : 2019
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Guide for Remedying Structural Silicone Glazing
Hardcopy , PDF
31-07-2024
English
15-10-2019
Committee |
C 24
|
DocumentType |
Guide
|
Pages |
4
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This guide provides recommendations for remedying existing structural sealant glazing (hereinafter called SSG) installations in situ. Remedial work may be necessary when a lite of glass is replaced, for routine maintenance, or after distress is discovered. This guide focuses on large-scale remedies, not isolated repairs or maintenance.
1.2Committee C24 is not aware of any comparable standards published by other organizations.
1.3This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM C 1401 : 2014 | Standard Guide for Structural Sealant Glazing |
ASTM C 1401 : 2014 : R2022 | Standard Guide for Structural Sealant Glazing |
ASTM C 717 : 2019 | Standard Terminology of Building Seals and Sealants |
ASTM E 997 : 2015 : R2021 | Standard Test Method for Evaluating Glass Breakage Probability Under the Influence of Uniform Static Loads by Proof Load Testing |
ASTM C 1394 : 2003 : R2012 | Standard Guide for In-Situ Structural Silicone Glazing Evaluation |
ASTM C 717 : 2024 | Standard Terminology of Building Seals and Sealants |
ASTM E 997 : 2015 | Standard Test Method for Evaluating Glass Breakage Probability Under the Influence of Uniform Static Loads by Proof Load Testing |
ASTM C 1392 : 2020 | Standard Guide for Evaluating Failure of Structural Sealant Glazing |
ASTM E 330 : 1997 : EDT 1 | Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference |
ASTM C 1401 : 2023 | Standard Guide for Structural Sealant Glazing |
ASTM E 997 : 1984 : R1992 : EDT 1 | Standard Test Method for Structural Performance of Glass in Exterior Windows, Curtain Walls, and Doors Under the Influence of Uniform Static Loads by Destructive Methods |