ASTM C 1618M : 2019
Current
The latest, up-to-date edition.
Standard Test Method for Concrete Sanitary Sewer Pipe by Negative (Vacuum) Air Pressure (Metric)
Hardcopy , PDF
English
01-01-2019
This test method covers procedures for testing of precast concrete pipe sections, prior to delivery, where maximum field leakage rates are specified.
Committee |
C 13
|
DocumentType |
Test Method
|
Pages |
3
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
Supersedes |
1.1This test method covers procedures for testing of precast concrete pipe sections, prior to delivery, where maximum field leakage rates are specified.
1.2Tests described in this standard are intended to be used at the point of manufacture of the concrete pipe and are not intended for testing installed pipe (for field tests see Practices C969 and C1214). The user of this specification is advised that individual or multiple pipe sections may be tested for the purpose of testing the pipe barrel and additionally the joints in straight alignment when multiple pipe sections are tested.
1.3Test times are based on leakage rates and therefore are proportional only to the pipe diameter and are constant for any length of test pipe or pipeline.
1.4Test times tabulated and the rate of air loss in this standard are based on successful testing of installed pipelines. However, since air and water have different physical properties, retests of some pipelines not meeting field air tests have been successful when tested with water. The leakage rates of 0.0017 CFM/ft2 and 0.0003 CFM/ft2, were determined empirically as the maximums for pipe to meet the 50 and 200 gal/(in. of internal diameter) (mile of sewer) (24h) test rates, respectively
1.5The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
Note 1:The availability of this test procedure for concrete pipe varies from location to location. Check with local supplier(s) for availability and recommendations.
1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See Section 6 for specific safety precautions.
1.7This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM C 822 : 2021 | Standard Terminology Relating to Concrete Pipe and Related Products |
ASTM C 1214 : 2019 | Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method |
ASTM C 969 : 2024 | Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines and Manholes |
ASTM C 822 : 2020 | Standard Terminology Relating to Concrete Pipe and Related Products |
ASTM C 1214 : 2013 | Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method |
ASTM C 1214 : 2002 | Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method |
ASTM C 1214 : 1994 : R2000 | Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method |
ASTM C 1214 : 2002 : R2009 | Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method |
ASTM C 969 : 2019 | Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.