• Shopping Cart
    There are no items in your cart

ASTM C 1726/C1726M : 2010

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Guide for Use of Modeling for Passive Gamma Measurements

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

01-03-2010

€67.30
Excluding VAT

CONTAINED IN VOL. 12.01, 2018 Describes the use of models with passive gamma-ray measurement systems. Mathematical models based on physical principles can be used to assist in calibration of gamma-ray measurement systems and in analysis of measurement data.

Committee
C 26
DocumentType
Guide
Pages
7
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 This guide addresses the use of models with passive gamma-ray measurement systems. Mathematical models based on physical principles can be used to assist in calibration of gamma-ray measurement systems and in analysis of measurement data. Some nondestructive assay (NDA) measurement programs involve the assay of a wide variety of item geometries and matrix combinations for which the development of physical standards are not practical. In these situations, modeling may provide a cost-effective means of meeting users data quality objectives.

1.2 A scientific knowledge of radiation sources and detectors, calibration procedures, geometry and error analysis is needed for users of this standard. This guide assumes that the user has, at a minimum, a basic understanding of these principles and good NDA practices (see Guide C1592), as defined for an NDA professional in Guide C1490. The user of this standard must have at least a basic understanding of the software used for modeling. Instructions or further training on the use of such software is beyond the scope of this standard.

1.3 The focus of this guide is the use of response models for high-purity germanium (HPGe) detector systems for the passive gamma-ray assay of items. Many of the models described in this guide may also be applied to the use of detectors with different resolutions, such as sodium iodide or lanthanum halide. In such cases, an NDA professional should determine the applicability of sections of this guide to the specific application.

1.4 Techniques discussed in this guide are applicable to modeling a variety of radioactive material including contaminated fields, walls, containers and process equipment.

1.5 This guide does not purport to discuss modeling for infinite plane in situ measurements. This discussion is best covered in ANSI N42.28.

1.6 This guide does not purport to address the physical concerns of how to make or set up equipment for in situ measurements but only how to select the model for which the in situ measurement data is analyzed.

1.7 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

BS ISO 19017 : 2015 COR 2017 GUIDANCE FOR GAMMA SPECTROMETRY MEASUREMENT OF RADIOACTIVE WASTE
ASTM C 1490 : 2014 : REDLINE Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel
14/30295796 DC : 0 BS ISO 19017 - GUIDE FOR GAMMA SPECTROMETRY MEASUREMENT OF RADIOACTIVE WASTE
I.S. EN ISO 19017:2017 GUIDANCE FOR GAMMA SPECTROMETRY MEASUREMENT OF RADIOACTIVE WASTE (ISO 19017:2015)
ISO 19017:2015 Guidance for gamma spectrometry measurement of radioactive waste
EN ISO 19017:2017 Guidance for gamma spectrometry measurement of radioactive waste (ISO 19017:2015)

ANSI N42.28 : 2008 CALIBRATION OF GERMANIUM DETECTORS FOR IN-SITU GAMMA-RAY MEASUREMENTS
ASTM C 1490 : 2014 : REDLINE Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.