ASTM C 497 : 2013
NA
Status of Standard is Unknown
Standard Test Methods for Concrete Pipe, Manhole Sections, or Tile
Hardcopy , PDF
English
01-02-2013
Committee |
C 13
|
DocumentType |
Test Method
|
Pages |
14
|
PublisherName |
American Society for Testing and Materials
|
Status |
NA
|
SupersededBy | |
Supersedes |
1.1These test methods cover testing of concrete pipe, manhole sections, and tile. The test methods described are used in production testing and acceptance testing to evaluate the properties provided for in the specifications.
1.3The test specimens shall not have been exposed to a temperature below 40°F for the 24 h immediately preceding the test.
1.4If any test specimen fails because of mechanical reasons such as failure of testing equipment or improper specimen preparation, it shall be discarded and another specimen taken.
1.5Specimens shall be selected in accordance with the specifications for the type of pipe or tile being tested.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.