Standard Specification for Nonreinforced Concrete Irrigation Pipe with Rubber Gasket Joints

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

01-09-2011

€67.30
Excluding VAT

Committee
C 13
DocumentType
Standard
Pages
5
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This specification covers nonreinforced concrete pipe with rubber gasket joints to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1.

1.2 A complete metric companion to Specification C505 has been developedC505M; therefore, no SI equivalents are presented in this specification.

Note 1—This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation.

TABLE 1 Standard Dimensions, Working Pressures, and Test Requirements

Internal
Designated
Diameter,
in.
Wall
Thickness,A
in.
Working
Pressure,B
ft
Required
Hydrostatic
Test
Pressure,C
psi
Minimum
Three-Edge-
Bearing
Load,
lbf/linear ft
6¾ 30401300
813040 1350
10 1¼30401400
12 1½30401500
15 17/830401650
18 2¼30401800
21 25/830401900
24 330402000

A Thinner walls are not prohibited on pipe units not over 4 ft in length, but the thickness of such walls shall not be less than the internal diameter divided by 10.

B With the exception of 21 and 24-in. pipe, higher working pressures are not prohibited to be used up to a maximum of 50 ft for 6 through 12-in. diameters, and 40 ft for 15 through 18-in. diameters. In these cases the strength of the pipe shall be increased to give minimum internal hydrostatic test pressures of at least three times the design working pressure when tested as specified in 10.4.

C For hydrostatic test requirements, refer to 10.4.