Standard Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation
Hardcopy , PDF
18-10-2024
English
01-09-2018
This practice presents a laboratory guide to determine the thermal resistance of loose-fill building insulations at mean temperatures between −20 and 55°C (−4 to 131°F).
Committee |
C 16
|
DocumentType |
Standard Practice
|
Pages |
10
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This practice presents a laboratory guide to determine the thermal resistance of loose-fill building insulations at mean temperatures between −20 and 55°C (−4 to 131°F).
1.2This practice applies to a wide variety of loose-fill thermal insulation products including but not limited to fibrous glass, rock/slag wool, or cellulosic fiber materials; granular types including vermiculite and perlite; pelletized products; and any other insulation material installed pneumatically or poured in place. It does not apply to products that change their character after installation either by chemical reaction or the application of binders or adhesives, nor does it consider the effects of structures, containments, facings, or air films.
1.3Since this practice is designed for reproducible product comparison, it measures the thermal resistance of an insulation material which has been preconditioned to a relatively dry state. Consideration of changes of thermal performance of a hygroscopic insulation by sorption of water is beyond the scope of this practice.
1.4The sample preparation techniques outlined in this practice do not cover the characterization of loose-fill materials intended for enclosed applications. For those applications, a separate sample preparation technique that simulates the installed condition will be required. However, even for those applications, some other aspects of this practice are applicable.
1.5The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM C 1630 : 2024 | Standard Guide for Development of Coverage Charts for Loose-Fill Thermal Building Insulations |
ASTM C 653 : 2024 | Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation |
ASTM C 1058/C1058M : 2010 : R2023 | Standard Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation |
ASTM C 764 : 2019 | Standard Specification for Mineral Fiber Loose-Fill Thermal Insulation |
ASTM E 861 : 2013 : R2021 | Standard Practice for Evaluating Thermal Insulation Materials for Use in Solar Collectors |
ASTM C 1373/C1373M : 2023 | Standard Practice for Determination of Thermal Resistance of Attic Insulation Systems Under Simulated Winter Conditions |
ASTM C 168 : 2019 | Standard Terminology Relating to Thermal Insulation |
ASTM C 1045 : 2019 | Standard Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions |
ASTM C 1114 : 2006 : R2013 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus |
ASTM C 1114 : 2006 : R2019 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus |
ASTM C 1045 : 2007 : R2013 | Standard Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions |
ASTM C 739 : 2024 | Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation |
ASTM C 653 : 2024 | Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation |
ASTM C 1363 : 2019 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ASTM C 1363 : 2005 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ASTM C 1363 : 1997 | Standard Test Method for the Thermal Performance of Building Assemblies by Means of a Hot Box Apparatus |
ASTM C 1373 : 2003 | Standard Practice for Determination of Thermal Resistance of Attic Insulation Systems Under Simulated Winter Conditions |
ASTM C 1114 : 2006 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus |
ASTM C 1045 : 2001 | Standard Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions |
ASTM C 518 : 2002 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
ASTM C 739 : 2017 | Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation |
ASTM C 168 : 2024 | Standard Terminology Relating to Thermal Insulation |
ASTM C 739 : 2021 : REV A | Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation |
ASTM C 1373 : 1998 | Standard Practice for Determination of Thermal Resistance of Attic Insulation Systems Under Simulated Winter Conditions |
ASTM C 167 : 2022 | Standard Test Methods for Thickness and Density of Blanket or Batt Thermal Insulations |
ASTM C 1114 : 2000 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus |
ASTM C 1363 : 2011 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ASTM C 518 : 2017 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
ASTM C 739 : 2021 | Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation |
ASTM C 518 : 2021 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
ASTM C 653 : 2017 | Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation |
ASTM C 1114 : 2000 : R2006 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus |
ASTM C 1045 : 1997 | Standard Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions |
ASTM C 167 : 2018 | Standard Test Methods for Thickness and Density of Blanket or Batt Thermal Insulations |
ASTM C 177 : 2019 : EDT 1 | Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus |
ASTM C 167 : 1998 | Standard Test Methods for Thickness and Density of Blanket or Batt Thermal Insulations |
ASTM C 168 : 2022 | Standard Terminology Relating to Thermal Insulation |
ASTM C 1373 : 2001 | Standard Practice for Determination of Thermal Resistance of Attic Insulation Systems Under Simulated Winter Conditions |
ASTM C 1045 : 2007 | Standard Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions |
ASTM C 1363 : 2024 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ASTM C 518 : 1998 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.