ASTM C 727 : 2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Installation and Use of Reflective Insulation in Building Constructions
Hardcopy , PDF
04-04-2024
English
01-05-2012
Committee |
C 16
|
DocumentType |
Standard Practice
|
Pages |
3
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 This practice has been prepared for use by the designer, specifier, and installer of reflective insulation for use in building construction. The scope is limited to recommendations relative to the use and installation of thermal insulation consisting of one or more surfaces, having an emittance of 0.1 or less such as metallic foil or metallic deposits unmounted or mounted on substrates and facing enclosed air spaces. The reflective insulation covered by this practice must meet the requirements of Specification C1224.
1.2 This practice covers the installation process from pre-installation inspection through post-installation procedure. It does not cover the production of the insulation materials.
1.3 This practice is not intended to replace the manufacturer's installation instructions, but shall be used in conjunction with such instructions. This practice is not intended to supercede local, state, or federal codes.
1.4 This practice assumes that the installer possesses a good working knowledge of the applicable codes and regulations, safety practices, tools, equipment, and methods necessary for the installation of thermal insulation materials. It also assumes that the installer understands the fundamentals of construction that affect the installation of insulation.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM C 1224 : 2015 | Standard Specification for Reflective Insulation for Building Applications |
ASTM C 1224 : 2009 | Standard Specification for Reflective Insulation for Building Applications |
ASTM C 1224 : 2001 | Standard Specification for Reflective Insulation for Building Applications |
ASTM C 1224 : 1999 | Standard Specification for Reflective Insulation for Building Applications |
ASTM C 1224 : 2011 | Standard Specification for Reflective Insulation for Building Applications |
ASTM C 1224 : 2003 | Standard Specification for Reflective Insulation for Building Applications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.