• Shopping Cart
    There are no items in your cart

ASTM C 783 : 1985 : R2015

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Core Sampling of Graphite Electrodes

Available format(s)

Hardcopy , PDF

Superseded date

10-08-2020

Language(s)

English

Published date

01-10-2015

€59.22
Excluding VAT

CONTAINED IN VOL. 05.05, 2017 Defines electric-arc furnace graphite electrodes, and covers a procedure and equipment for obtaining core samples from electrodes in a manner that does not destroy the electrode nor prevent its subsequent use as originally intended.

Committee
D 02
DocumentType
Standard Practice
Pages
2
ProductNote
Reconfirmed 2015
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This practice was developed for electric-arc furnace graphite electrodes, and covers a procedure and equipment for obtaining core samples from electrodes in a manner that does not destroy the electrode nor prevent its subsequent use as originally intended. However, the minimum electrode diameter, for which extraction of a core sample using this practice does not influence subsequent use, is influenced by the particular application and must be determined by the user. Graphite electrodes for use in electric arc furnaces are usually solid cylinders of graphite with threaded sockets machined in each end.

1.2The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Note 1:The following ASTM standards are noted as sources of useful information: Test Methods C559, C611, C651, C747, C1025, and C1039.

ASTM C 1025 : 1991 : R2010 : EDT 1 Standard Test Method for Modulus of Rupture in Bending of Electrode Graphite
ASTM C 1025 : 1991 : R2005 Standard Test Method for Modulus of Rupture in Bending of Electrode Graphite
ASTM C 1039 : 1985 : R2015 Standard Test Methods for Apparent Porosity, Apparent Specific Gravity, and Bulk Density of Graphite Electrodes
ASTM C 1039 : 1985 : R2010 : EDT 1 Standard Test Methods for Apparent Porosity, Apparent Specific Gravity, and Bulk Density of Graphite Electrodes
ASTM C 1025 : 2015 : REDLINE Standard Test Method for Modulus of Rupture in Bending of Electrode Graphite
ASTM C 1025 : 1991 : R2000 Standard Test Method for Modulus of Rupture in Bending of Electrode Graphite
ASTM C 747 : 2016 : REDLINE Standard Test Method for Moduli of Elasticity and Fundamental Frequencies of Carbon and Graphite Materials by Sonic Resonance
ASTM C 1039 : 1985 : R2000 Standard Test Methods for Apparent Porosity, Apparent Specific Gravity, and Bulk Density of Graphite Electrodes
ASTM C 1039 : 1985 : R2005 Standard Test Methods for Apparent Porosity, Apparent Specific Gravity, and Bulk Density of Graphite Electrodes
ASTM C 559 : 2016 : REDLINE Standard Test Method for Bulk Density by Physical Measurements of Manufactured Carbon and Graphite Articles
ASTM C 1025 : 2015 Standard Test Method for Modulus of Rupture in Bending of Electrode Graphite
ASTM C 651 : 2015 : REDLINE Standard Test Method for Flexural Strength of Manufactured Carbon and Graphite Articles Using Four-Point Loading at Room Temperature

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.