1.1These test methods cover procedures for sampling and testing untreated paper to be used as an electrical insulator or as a constituent of a composite material used for electrical insulating purposes.
1.1.1Untreated papers are thin, fibrous sheets normally laid down from a water suspension of pulped fibers (usually cellulosic) with or without various amounts of nonfibrous ingredients, and which are calendared, if required, to obtain desired thickness and density. Nevertheless, these test methods are applicable, generally although not invariably, to papers formed by other means, to papers modified (during or after formation) by additions, and to papers given subsequent mechanical treatments such as creping.
1.1.2As an electrical insulating and dielectric material, paper is considered “untreated” until it is subjected to a manufacturing process such as drying, impregnation, or varnish treatment.
1.1.3The test methods given herein were developed specifically for papers having a thickness of 0.75 mm (0.030 in.) or less. A number of these test methods are also suitable for use on other materials such as pulps or boards. Refer to Test Methods D3376 or D3394 to determine which tests are applicable to pulps or electrical insulating boards. In the paper industry, some products in thicknesses of less than 0.75 mm are termed “paperboard”. Such products are included within the scope of these methods.
1.1.4These test methods are applicable to flexible fibrous-mat materials formed from suspensions of fiber in fluids other than water. Thicknesses of these mats approach 2 mm, and the fibers contained are possibly natural, synthetic, organic, or inorganic; fillers that are natural, synthetic, organic, or inorganic; and flexible polymeric binder materials.
1.2The procedures appear in the following sections:
Procedure | Sections | ASTM or TAPPI Reference |
Absorption (Rise of Water) | 78 to 83 | . . . |
Acidity-Alkalinity-pH | 45 to 54 | E70 |
Air Resistance | 98 to 101 | D726 |
Aqueous Extract Conductivity | 55 to 64 | . . . |
Ash Content | 40 to 44 | D586 |
Bursting Strength | 102 to 107 | D774/D774M |
Chlorides (Water-Extractable) | 165 to 183 | . . . |
Conditioning | 15 | D6054 |
Conducting Paths | 138 to 151 | . . . |
Density, Apparent | 29 to 33 | . . . |
Dielectric Strength | 152 to 157 | D149 |
Dimensions of Sheet, Rolls and Cores | 16 to 24 | D374 |
Dissipation Factor and Permittivity | 158 to 164 | D150 |
Edge-Tearing Resistance | 126 to 130 | D827 |
Fiber Analysis | 74 to 77 | D1030 |
Folding Endurance | 108 to 110 | T 423 and D2176 |
Grammage | 25 to 28 | D646 |
Permittivity | 158 to 164 | D150 |
Heat Stability in Air | 131 to 137 | D827 |
Impregnation Time | 84 to 91 | . . . |
Internal-Tearing Resistance | 121 to 125 | D689 or T 414 |
Moisture Content | 34 to 39 | D644 and D3277 |
Particulate Copper | 193 to 202 | . . . |
Particulate Iron | 184 to 192 | . . . |
Reagents | 4 | D1193 |
Reports | 14 | E29 |
Sampling | 6 to 13 | D3636 |
Silver Tarnishing by Paper and Paperboard | 203 to 206 | T 444 |
Solvent-Soluble Matter | 65 to 73 | . . . |
Surface Friction | 92 to 97 | D528 and T 455 |
Tensile Properties | 111 to 120 | D76, E4 |
Thickness (see Dimensions) | 16 to 24 | D374 |
1.3The tests for Holes and Felt Hair Inclusions and the Stain Test for Fine Pores, have been removed from this compilation of test methods. These test methods were specific to grades of capacitor paper formerly covered by Specification D1930, which has been withdrawn.
Note 1:This compilation of test methods is closely related to IEC Publication 60554-2. Not all of the individual methods included herein are included in IEC 60554-2, nor are all of the methods in IEC 60554-2 included in this standard. The individual procedures as described in the two standards are in general sufficiently close to each other that it is reasonable to expect that test results obtained by most of the procedures specified in either standard will not differ significantly. However, before assuming that a procedure in these test methods is exactly equivalent to an IEC 60554-2 procedure, the written procedures must be compared closely, and if it seems advisable, test results by the two procedures are compared.
1.4The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See 43.2.1, 71.1, 143.1, 148.1 and 156.1 for specific hazards.
1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D 115 : 2017 | Standard Test Methods for Testing Solvent Containing Varnishes Used for Electrical Insulation |
ASTM D 1711 : 2022 | Standard Terminology Relating to Electrical Insulation |
ASTM D 3394 : 2016 : R2022 | Standard Test Methods for Sampling and Testing Electrical Insulating Board |
ASTM D 1677 : 2017 | Standard Methods for Sampling and Testing Untreated Mica Paper Used for Electrical Insulation |
ASTM D 3376 : 2018 | Standard Test Methods of Sampling and Testing Pulps to be Used in the Manufacture of Electrical Insulation |
ASTM D 619 : 2021 | Standard Test Methods for Vulcanized Fibre Used for Electrical Insulation |
ASTM D 1304 : 1999 : R2020 : EDT 1 | Standard Test Methods for Adhesives Relative to Their Use as Electrical Insulation |
ASTM D 2413 : 2016 : R2022 | Standard Practice for Preparation of Insulating Paper and Board Impregnated with a Liquid Dielectric |
ASTM D 1305 : 2016 : R2022 | Standard Specification for Electrical Insulating Paper and Paperboard—Sulfate (Kraft) Layer Type |
ASTM D 7812 : 2022 | Standard Test Method for Tensile Testing of Aramid Paper |
ASTM D 1193 : 2024 | Standard Specification for Reagent Water |
ASTM D 3636 : 2024 | Standard Practice for Sampling and Judging Quality of Solid Electrical Insulating Materials |
ASTM D 689 : 2017 | Standard Test Method for Internal Tearing Resistance of Paper |
ASTM E 70 : 2019 | Standard Test Method for pH of Aqueous Solutions With the Glass Electrode |
ASTM D 1711 : 2024 : REV A | Standard Terminology Relating to Electrical Insulation |
ASTM D 586 : 2019 | Standard Test Method for Ash and Organic Matter Content of Degradable Erosion Control Products |
ASTM D 586 : 2023 | Standard Test Method for Ash and Organic Matter Content of Degradable Erosion Control Products |
ASTM D 3636 : 2019 | Standard Practice for Sampling and Judging Quality of Solid Electrical Insulating Materials |
ASTM E 4 : 2021 | Standard Practices for Force Calibration and Verification of Testing Machines |
ASTM D 1711 : 2024 | Standard Terminology Relating to Electrical Insulation |
ASTM D 689 : 2017 : R2024 | Standard Test Method for Internal Tearing Resistance of Paper |
ASTM D 1193 : 2006 : R2018 | Standard Specification for Reagent Water |
ASTM E 70 : 2024 | Standard Test Method for pH of Aqueous Solutions With the Glass Electrode |
ASTM E 4 : 2024 | Standard Practices for Force Calibration and Verification of Testing Machines |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.