ASTM D 229 : 2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Methods for Rigid Sheet and Plate Materials Used for Electrical Insulation
Hardcopy , PDF
11-11-2014
English
15-01-2009
Committee |
D 09
|
DocumentType |
Test Method
|
Pages |
17
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 These test methods cover procedures for testing rigid electrical insulation normally manufactured in flat sheet or plate form. They are generally used as terminal boards, spacers, voltage barriers, and circuit boards.
Note 1—For tests applying to vulcanized fibre reference should be made to Test Methods D 619
Note 2—This standard resembles IEC 60893-2, Specification for Rigid Industrial Laminated Sheets Based On Thermosetting Resins for Electrical Purpose, Methods of Tests.
1.2 The test methods appear in the following sections:
Test | Sections | ASTM Test Method |
Acetone extractable matter | 83 to 84 | D 494 |
Arc resistance | 47 | D 495 |
Ash | 56 to 60 | ... |
Bonding strength | 49 to 54 | ... |
Burning rate and flame resistance | 61 to 75 | ... |
Compressive strength | 25 | D 695 |
Conditioning | 4 | D 6054 |
Dissipation factor | 34 to 40 | D 669 |
Dielectric strength | 28 to 33 | D 149 |
Expansion (linear thermal) | 76 | D 696 |
Flexural properties | 12 to 24 | D 790 |
Hardness (Rockwell) | 55 | D 785 |
Insulation resistance and resistivity | 41 to 46 | D 257 |
Permittivity | 34 to 40 | D 150 |
Resistance to impact | 26 | D 256 |
Tensile properties | 7 to 11 | D 638 |
Thickness | 5 to 6 | D 374 |
Tracking resistance | 48 | D 2132 |
Warp or twist | 77 to 82 | ... |
Water absorption | 27 | D 570 |
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This is a fire-test-response standard. See Sections 61 through 75, which are the procedures for burning rate and flame resistance.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 31.1 and 1.6.
1.6 This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.
17.1 This test method covers the determination of flexural properties at elevated temperature, and as a function of time of exposure to elevated temperature.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.