• Shopping Cart
    There are no items in your cart

ASTM D 229 : 2013

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Methods for Rigid Sheet and Plate Materials Used for Electrical Insulation

Available format(s)

Hardcopy , PDF

Superseded date

13-03-2019

Superseded by

ASTM D 229 : 2019

Language(s)

English

Published date

14-11-2013

€74.48
Excluding VAT

Committee
D 09
DocumentType
Test Method
Pages
18
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1These test methods cover procedures for testing rigid electrical insulation normally manufactured in flat sheet or plate form. They are generally used as terminal boards, spacers, voltage barriers, and circuit boards.

1.2Use Test Methods D619 (withdrawn) or Specification D710 for tests applying to vulcanized fibre.

1.3Some of the test methods contained in this standard are similar to those contained in IEC 60893-2, which applies to rigid industrial laminated sheets based on thermosetting resins for electrical purposes.

1.4The test methods appear in the following sections:

Test

Sections

ASTM
Test
Method

Acetone extractable matter

83 to 84

D494

Arc resistance

47

D495

Ash

56 to 60

...

Bonding strength

49 to 54

...

Burning rate and flame resistance

61 to 75

...

Compressive strength

25

D695

Conditioning

4

D6054

Dissipation factor

34 to 40

D669

Dielectric strength

28 to 33

D149

Expansion (linear thermal)

76

D696

Flexural properties

12 to 24

D790

Hardness (Rockwell)

55

D785

Insulation resistance and resistivity

41 to 46

D257

Permittivity

34 to 40

D150

Resistance to impact

26

D256

Tensile properties

7 to 11

D638

Thickness

5 to 6

D374

Tracking resistance

48

D2132

Warp or twist

77 to 82

...

Water absorption

27

D570


1.5The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.6This is a fire-test-response standard. See Sections 61 through 75, which are the procedures for burning rate and flame resistance.

1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 31.1 and 1.8.

1.8This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

1.9Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.