ASTM D 2590/D2590M : 1998 : R2011 : EDT 1
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Sampling Chrysotile Asbestos
Hardcopy , PDF
03-05-2019
English
01-11-2011
CONTAINED IN VOL. 04.05, 2015 Defines procedures for taking a composite or a master composite sample, at the mine or at the factory or from a consignment, of a lot of milled asbestos fiber used as raw material in the chrysotile asbestos industry, conditioning this sample and reducing it in quantity through a series of steps to provide a relatively small test specimen of loose asbestos fibers, representative of the lot and suitable for the determination of a single property.
Committee |
C 17
|
DevelopmentNote |
Supersedes ASTM D 2590. (02/2012)
|
DocumentType |
Test Method
|
Pages |
6
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 This test method covers procedures for taking a composite or a master composite sample, at the mine or at the factory or from a consignment, of a lot of milled asbestos fiber used as raw material in the chrysotile asbestos industry, conditioning this sample and reducing it in quantity through a series of steps to provide a relatively small test specimen of loose asbestos fibers, representative of the lot and suitable for the determination of a single property.
1.2 This sampling method is suitable for taking test specimens of chrysotile asbestos for Test Methods: C1119, C1120, C1121, C1122, C1123, C1124, C1125, C1162, D1118, D2589, D2752, D2946, D2947, D2985, D2987, D3639, D3752 and D3880.
1.3 Test Method D3879 covers the sampling of amphibole asbestos fibers.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. ^REFERENCE:
ASTM Standards:
C1119 Test Method for Vacuum Drainage of Asbestos-Cement Mixes
C1120 Test Method for Wash Test of Asbestos
C1121 Test Method for Turner and Newall (T and N) Wet-Length Classification of Asbestos
C1122 Test Method for Wet Volume of Asbestos
C1123 Test Method for Compressibility and Recovery of Asbestos
C1124 Test Method for Kerosene Retention of Asbestos
C1125 Test Method for Penetration Index of Asbestos
C1162 Test Method for Loose Density of Asbestos
D1118 Test Method for Magnetic Rating of Asbestos Fiber and Asbestos Textiles
D2589 Test Method for McNett Wet Classification of Dual Asbestos Fiber
D2752 Test Methods for Air Permeability of Asbestos Fibers
D2946 Terminology for Asbestos and Asbestos–Cement Products
D2947 Test Method for Screen Analysis of Asbestos Fibers
D2985 Test Method for Color of Asbestos
D2987 Test Method for Moisture Content of Asbestos Fiber
D3639 Test Method for Classification of Asbestos by Quebec Standard Test
D3752 Test Method for Strength Imparted by Asbestos to a Cementitious Matrix
D3879 Test Method for Sampling Amphibole Asbestos (Withdrawn)
D3880 Test Method for Asbestos Strength Units
2.2 ASTM Adjuncts:
Laboratory Filter Drawings
ASTM C 1121/C1121M : 2004 : R2009 : EDT 1 | Standard Test Method for Turner and Newall (T and N) Wet-Length Classification of Asbestos |
ASTM C 1124/C1124M : 1990 : R2015 | Standard Test Method for Kerosene Retention of Asbestos (Withdrawn 2021) |
ASTM C 1125 : 1989 : R2009 | Standard Test Method for Penetration Index of Asbestos |
ASTM C 1162/C1162M : 1990 : R2009 : EDT 1 | Standard Test Method for Loose Density of Asbestos |
ASTM C 1125 : 1989 : R2004 | Standard Test Method for Penetration Index of Asbestos |
ASTM C 1121/C1121M : 2004 : R2015 | Standard Test Method for Turner and Newall (T and N) Wet-Length Classification of Asbestos (Withdrawn 2021) |
ASTM C 1125 : 1989 : R2004 : EDT 1 | Standard Test Method for Penetration Index of Asbestos |
ASTM C 1125 : 1989 : R1999 : EDT 1 | Standard Test Method for Penetration Index of Asbestos |
ASTM C 1124/C1124M : 1990 : R2009 : EDT 1 | Standard Test Method for Kerosene Retention of Asbestos |
ASTM C 1119/C1119M : 1990 : R2009 : EDT 1 | Standard Test Method for Vacuum Drainage of Asbestos-Cement Mixes |
ASTM C 1122/C1122M : 1990 : R2009 : EDT 1 | Standard Test Method for Wet Volume of Asbestos |
ASTM C 1122/C1122M : 1990 : R2015 | Standard Test Method for Wet Volume of Asbestos (Withdrawn 2021) |
ASTM C 1125 : 1989 : R2015 | Standard Test Method for Penetration Index of Asbestos (Withdrawn 2021) |
ASTM C 1162/C1162M : 1990 : R2015 | Standard Test Method for Loose Density of Asbestos (Withdrawn 2021) |
ASTM C 1119/C1119M : 1990 : R2015 | Standard Test Method for Vacuum Drainage of Asbestos-Cement Mixes (Withdrawn 2021) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.