ASTM D 2752/D2752M : 1988 : R2011 : EDT 1
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Methods for Air Permeability of Asbestos Fibers
Hardcopy , PDF
06-05-2019
English
01-11-2011
CONTAINED IN VOL. 04.05, 2015 Defines the measurement of the relative degree of openness or degree of fiberization of milled asbestos fiber by air permeability instruments.
Committee |
C 17
|
DevelopmentNote |
Supersedes ASTM D 2752. (02/2012)
|
DocumentType |
Test Method
|
Pages |
10
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 These test methods cover the measurement of the relative degree of openness or degree of fiberization of milled asbestos fiber by air permeability instruments.
1.2 Method A is the recommended procedure and describes a determination by means of the Rapid Surface Area apparatus. This test method is limited to fibers with an effective surface area in the range from 10 to 250 dm2/g [490 to 12 000 ft2/lb].
1.3 Method B is an alternative procedure and covers the use of the Dyckerhoff apparatus. This test method is limited to fibers within the range from 10 to 600 Dyckerhoff seconds.
1.4 Only those asbestos specimens which are of similar specific gravities will bear strict comparison by these air permeability methods since differences in density result in specimens being tested under different conditions of porosity.
1.5 Samples containing excessive quantities of nonfibrous particles or contaminants will not give reliable or meaningful results.
1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.7 Warning—Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysotile asbestos, refer to “Safe Use of Chrysotile: A Manual on Preventive and Control Measures.”
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. ^REFERENCE:
ASTM Standards:
D2590 Test Method for Sampling Chrysotile Asbestos
D3879 Test Method for Sampling Amphibole Asbestos (Withdrawn)
E11 Specification for Woven Wire Test Sieve Cloth and Test Sieves
E177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods
Other Standard:
NNN-P-1475B Federal Specification for Paper, Filter, Analytical
ASTM C 1121/C1121M : 2004 : R2015 | Standard Test Method for Turner and Newall (T and N) Wet-Length Classification of Asbestos (Withdrawn 2021) |
ASTM C 1121/C1121M : 2004 : R2009 : EDT 1 | Standard Test Method for Turner and Newall (T and N) Wet-Length Classification of Asbestos |
ASTM E 177 : 2014 : REDLINE | Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods |
NNN-P-1475 Revision B:1970 | PAPER FILTER ANALYTICAL |
ASTM E 11 : 2017 : REDLINE | Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.