ASTM D 348 : 2013
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Standard Test Methods for Rigid Tubes Used for Electrical Insulation (Withdrawn 2020)
Hardcopy , PDF
09-03-2020
English
01-11-2013
Committee |
D 09
|
DocumentType |
Test Method
|
Pages |
6
|
PublisherName |
American Society for Testing and Materials
|
Status |
Withdrawn
|
Supersedes |
1.1These test methods cover the testing of rigid tubes used in electrical insulation. These tubes include many types made from fibrous sheets of basic materials, such as cellulose, glass, or nylon, in the form of paper, woven fabrics, or mats, bonded together by natural or synthetic resins or by adhesives. Such tubes include vulcanized fiber and thermosetting laminates, as well as tubes made from cast, molded, or extruded natural or synthetic resins, with or without fillers or reinforcing materials.
1.2Tubes tested by these test methods are most commonly circular in cross section; however, noncircular shapes are also in commercial use. To the extent that the individual methods are compatible with a particular noncircular shape, these test methods are applicable to these other shapes. For tests on noncircular tubes, appropriate comments shall be included in the test report, including details of orientation of test specimens with respect to the cross section of the tube.
1.3The procedures appear in the following sections:
Procedure | Sections | ASTM Test Method |
Compressive Strength (Axial and Diametral) | 12 to 17 | E4 |
Conditioning. | 4 | ... |
Density | 20 to 24 | ... |
Dielectric Strength | 25 to 32 | D149 |
Dimensional Measurements | 5 | D668 |
Dissipation Factor and Permittivity | 33 to 35 | D150 |
Tensile Strength | 6 to 11 | E4 |
Water Absorption | 18 to 19 | D570 |
1.4The values stated in inch-pound units are to be regarded as the standard. SI units in parentheses are for information only.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see 27.1.1.
ASTM D 1711 : 2002 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2011 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2011 : REV A | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2013 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 1999 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2014 : REV A | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2015 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2014 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2020 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2008 | Standard Terminology Relating to Electrical Insulation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.