ASTM D 348 : 2013

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Standard Test Methods for Rigid Tubes Used for Electrical Insulation (Withdrawn 2020)

Available format(s)

Hardcopy , PDF

Withdrawn date

09-03-2020

Language(s)

English

Published date

01-11-2013

€67.30
Excluding VAT

Committee
D 09
DocumentType
Test Method
Pages
6
PublisherName
American Society for Testing and Materials
Status
Withdrawn
Supersedes

1.1These test methods cover the testing of rigid tubes used in electrical insulation. These tubes include many types made from fibrous sheets of basic materials, such as cellulose, glass, or nylon, in the form of paper, woven fabrics, or mats, bonded together by natural or synthetic resins or by adhesives. Such tubes include vulcanized fiber and thermosetting laminates, as well as tubes made from cast, molded, or extruded natural or synthetic resins, with or without fillers or reinforcing materials.

1.2Tubes tested by these test methods are most commonly circular in cross section; however, noncircular shapes are also in commercial use. To the extent that the individual methods are compatible with a particular noncircular shape, these test methods are applicable to these other shapes. For tests on noncircular tubes, appropriate comments shall be included in the test report, including details of orientation of test specimens with respect to the cross section of the tube.

1.3The procedures appear in the following sections:

Procedure

Sections

ASTM Test Method
Reference

Compressive Strength (Axial and Diametral)

12 to 17

  E4

Conditioning.

4

  ...

Density

20 to 24

  ...

Dielectric Strength

25 to 32

  D149

Dimensional Measurements

5

  D668

Dissipation Factor and Permittivity

33 to 35

  D150

Tensile Strength

6 to 11

  E4

Water Absorption

18 to 19

  D570


1.4The values stated in inch-pound units are to be regarded as the standard. SI units in parentheses are for information only.

1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see 27.1.1.

ASTM D 1711 : 2002 Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2011 Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2011 : REV A Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2013 Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 1999 Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2014 : REV A Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2015 Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2014 Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2020 Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2008 Standard Terminology Relating to Electrical Insulation

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.