Supersedes |
1.1 This specification covers machine-made fiberglass pipe, 8 in. (200 mm) through 156 in. (4000 mm), for use in pressure systems for conveying sanitary sewage, storm water, and many industrial wastes, and corrosive fluids. Both glass-fiber-reinforced thermosetting-resin pipe (RTRP) and glass-fiber-reinforced polymer mortar pipe (RPMP) are fiberglass pipes. This standard is suited primarily for pipes to be installed in buried applications, although it may be used to the extent applicable for other installations such as, but not limited to, jacking, tunnel lining and slip-lining and rehabilitation of existing pipelines. Pipe covered by this specification is intended to operate at internal gage pressures of 450 psi (3103 kPa) or less.
Note 1—For the purposes of this standard, polymer does not include natural polymers.
1.2 The values given in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information purposes only.
1.3 The following precautionary caveat pertains only to the test method portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Note 2—There is no known ISO equivalent to this standard.
TABLE 1 General Designation Requirements for Fiberglass Pressure Pipe
Desig- nation | Property | Cell LimitsA | |||
---|---|---|---|---|---|
1 | Type | 1 glass-fiber-reinforced thermosetting polyesterB resin mortar (RPMP polyester)B | 2 glass-fiber-reinforced thermosetting polyesterB resin (RTRP polyester)B | 3 glass-fiber-reinforced thermosetting epoxy resin mortar (RPMP epoxy) | 4 glass-fiber-reinforced thermosetting epoxy resin (RTRP epoxy) |
2 | Liner | 1 reinforced thermoset liner | 2 non-reinforced thermoset liner | 3 thermoplastic liner | 4 no liner |
3 | Grade | 1 Polyester resin surface layer reinforcedB | 2 polyesterB resin surface layer nonreinforcedB | 3 polyesterB resin and sand surface layer nonreinforced | 4 epoxy resin surface layer reinforced | 5 epoxy resin surface layer nonreinforced | 6 No surface layer |
4 | ClassC | C50 | C100 | C150 | C200 | C250 | C300 | C350 | C400 | C450 |
5 | Pipe Stiffness psi (kPa) | A 9 (62) | B 18 (124) | C 36 (248) | D 72 (496)ABC |
A The cell-type format provides the means of identification and specification of piping materials. This cell-type format, however, is subject to misapplication since unobtainable property combinations can be selected if the user is not familiar with commercially available products. The manufacturer should be consulted.
B For the purposes of this standard, polyester includes vinyl ester resin.
C Based on operating pressure in psig (numerals).
ASTM D 5421 : 2015 | Standard Specification for Contact Molded “Fiberglass” (Glass-Fiber-Reinforced Thermosetting Resin) Flanges |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.