ASTM D 3839 : 1994 : REV A
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Underground Installation of "Fiberglass" (Glass-Fiber- Reinforced Thermosetting-Resin) Pipe
11-11-2014
01-01-1994
Committee |
D 20
|
DocumentType |
Standard Practice
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 This practice establishes procedures for the burial of pressure and nonpressure "fiberglass" (glass-fiber-reinforced thermosetting-resin) pipe in many typically encountered soil conditions. Included are recommendations for trenching, placing pipe, joining pipe, placing and compacting backfill, and monitoring deflection levels. Guidance for installation of fiberglass pipe in subaqueous conditions is not included.
1.2 Product standards for fiberglass pipe encompass a wide range of product variables. Diameters range from 1 in. to 12 ft and pipe stiffness range from 9 to over 72 psi with internal pressure ratings up to several thousand pound-force per square inch. This standard does not purport to consider all of the possible combinations of pipe, soil types, and natural ground conditions that may occur. The recommendations in this practice may need to be modified or expanded to meet the needs of some installation conditions. In particular, fiberglass pipe with diameters of a few inches are generally so stiff that they are frequently installed in accordance with different guidelines. Consult with the pipe manufacturer for guidance on which practices are applicable to these particular pipes.
1.3 The scope of this practice excludes product-performance criteria such as a minimum pipe stiffness, maximum service deflection, or long-term strength. Such parameters may be contained in product standards or design specifications, or both, for fiberglass pipe. It is incumbent upon the specified product manufacturer or project engineer to verify and ensure that the pipe specified for an intended application, when installed in accordance with procedures outlined in this practice, will provide a long-term, satisfactory performance in accordance with criteria established for that application.
Note 1-There is no similar or equivalent ISO standard. Note 2-A discussion of the importance of deflection and a presentation of a simplified method to approximate field deflections are given in AWWA C950.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D 2517 : 2018 | Standard Specification for Reinforced Epoxy Resin Gas Pressure Pipe and Fittings |
ASTM F 1668 : 2016 | Standard Guide for Construction Procedures for Buried Plastic Pipe |
ASTM D 6088 : 2006 : R2016 | Standard Practice for Installation of Geocomposite Pavement Drains |
ASTM F 1216 : 2016 | Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.