ASTM D 3934 : 2014

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Flash/No Flash Test—Equilibrium Method by a Closed-Cup Apparatus

Available format(s)

Hardcopy , PDF

Superseded date

12-06-2020

Superseded by

ASTM D 3934 : 2020

Language(s)

English

Published date

15-12-2014

€59.22
Excluding VAT

Committee
D 01
DocumentType
Test Method
Pages
4
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This test method covers the determination of whether a liquid complies with the closed-cup flash point requirements in government regulations, or in specifications, or as agreed between the purchaser and the seller.

1.2This test method is limited to a temperature range between 0 and 110°C (32 and 230°F).

1.3The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.4WarningMercury has been designated by many regulatory agencies as a hazardous material that can cause central nervous system, kidney and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury containing products. See the applicable product Safety Data Sheet (SDS) for details and EPA’s website, http://www.epa.gov/mercury/faq.htm, for additional information. Users should be aware that selling mercury and/or mercury containing products into your state or country may be prohibited by law.

1.5This standard should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use.

1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E 502 : 2007 : R2013 Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods

ASTM E 2877 : 2012 : EDT 1 Standard Guide for Digital Contact Thermometers
ASTM D 3828 : 2002 Standard Test Methods for Flash Point by Small Scale Closed Cup Tester
ASTM D 3941 : 2014 Standard Test Method for Flash Point by the Equilibrium Method With a Closed-Cup Apparatus
ASTM D 3828 : 2012 : REV A Standard Test Methods for Flash Point by Small Scale Closed Cup Tester
ASTM D 3828 : 1998 Standard Test Methods for Flash Point by Small Scale Closed Tester
ASTM D 3828 : 2007 Standard Test Methods for Flash Point by Small Scale Closed Cup Tester
ASTM E 2251 : 2007 Standard Specification for Liquid-in-Glass ASTM Thermometers with Low-Hazard Precision Liquids
ASTM D 3278 : 1996 : EDT 1 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus
ASTM E 2251 : 2003 : REV A Standard Specification for Liquid-in-Glass ASTM Thermometers with Low-Hazard Precision Liquids
ASTM D 3828 : 2007 : REV A Standard Test Methods for Flash Point by Small Scale Closed Cup Tester
ASTM D 3941 : 1990 : R2001 Standard Test Method for Flash Point by the Equilibrium Method With a Closed-Cup Apparatus
ASTM E 2251 : 2003 Standard Specification for Liquid-in-Glass ASTM Thermometers with Low-Hazard Precision Liquids
ASTM D 3828 : 2012 Standard Test Methods for Flash Point by Small Scale Closed Cup Tester
ASTM D 3278 : 1982 : EDT 1 Standard Test Methods for Flash Point of Liquids by Setaflash Closed-Cup Apparatus
ASTM E 2251 : 2010 Standard Specification for Liquid-in-Glass ASTM Thermometers with Low-Hazard Precision Liquids
ASTM D 3828 : 2016 : REV A Standard Test Methods for Flash Point by Small Scale Closed Cup Tester
ASTM E 2251 : 2011 Standard Specification for Liquid-in-Glass ASTM Thermometers with Low-Hazard Precision Liquids
ASTM E 2877 : 2012 : R2019 Standard Guide for Digital Contact Thermometers
ASTM E 2251 : 2014 Standard Specification for Liquid-in-Glass ASTM Thermometers with Low-Hazard Precision Liquids
ASTM D 3828 : 2005 Standard Test Methods for Flash Point by Small Scale Closed Cup Tester
ASTM E 2877 : 2012 Standard Guide for Standard Guide for Digital Contact Thermometers
ASTM D 3828 : 2009 Standard Test Methods for Flash Point by Small Scale Closed Cup Tester
ASTM D 3941 : 1990 : R2007 Standard Test Method for Flash Point by the Equilibrium Method With a Closed-Cup Apparatus
ASTM D 3941 : 1990 : R1996 : EDT 1 Standard Test Method for Flash Point by the Equilibrium Method With a Closed-Cup Apparatus
ASTM D 3278 : 1996 : R2004 : EDT 1 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus
ASTM E 1137 : 1997 Standard Specification for Industrial Platinum Resistance Thermometers
ASTM D 3828 : 2016 Standard Test Methods for Flash Point by Small Scale Closed Cup Tester
ASTM D 3278 : 1996 : R2011 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus (Withdrawn 2020)
ASTM D 3828 : 1997 Standard Test Methods for Flash Point by Small Scale Closed Tester

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.