• ASTM D 3977 : 1997

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Standard Test Methods for Determining Sediment Concentration in Water Samples

    Available format(s):  Hardcopy, PDF

    Superseded date:  11-11-2014

    Language(s):  English

    Published date:  31-12-2010

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 11.02, 2017 Defines the determination of sediment concentrations in water and wastewater samples collected from lakes, reservoirs, ponds, streams, and other water bodies.

    Scope - (Show below) - (Hide below)

    1.1 These test methods cover the determination of sediment concentrations in water and wastewater samples collected from lakes, reservoirs, ponds, streams, and other water bodies. In lakes and other quiescent-water bodies, concentrations of sediment in samples are nearly equal to concentrations at sampling points; in most instances, sample concentrations are not strongly influenced by collection techniques. In rivers and other flowing-water bodies, concentrations of sediment in samples depend upon the manner in which the samples are collected. Concentrations in isokinetically-collected samples can be multiplied by water discharges to obtain sediment discharges in the vicinity of the sampling points.

    1.2 The procedures given in these test methods are used by the Agricultural Research Service, Geological Survey, National Resources Conservation Service, Bureau of Reclamation, and other agencies responsible for studying water bodies. These test methods are adapted from a laboratory-procedure manual and a quality-assurance plan.

    1.3 These test methods include:

    Test Method A-Evaporation (Sections 8-13)
    Test Method B-Filtration (Sections 14-19)
    Test Method C-Wet-sieving-filtration (Sections 20-25)

    1.4 Test Method A can be used only on sediments that settle within the allotted storage time of the samples which usually ranges from a few days to a few weeks. A correction factor must be applied if dissolved-solids concentration exceeds about 10% of the sediment concentration.

    1.5 Test Method B can be used only on samples containing sand concentrations less than about 10 000 ppm and clay concentrations less than about 200 ppm. The sediment need not be settleable because filters are used to separate water from the sediment. Correction factors for dissolved solids are not required.

    1.6 Test Method C can be used if two concentration values are required; one for sand-size particles and one for the combination of silt and clay-size particles. The silt-clay fraction need not be settleable.

    1.7 These test methods must not be confused with turbidity measurements discussed in Test Method D 1889. Turbidity is the optical property of a sample that causes light rays to be scattered and absorbed; it is not an accurate measure of the mass or concentration of sediment in the sample.

    1.8 These test methods contain some procedures similar to those in Test Methods D 1888 which pertains to measuring particulate and dissolved matter in water.

    1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

    General Product Information - (Show below) - (Hide below)

    Committee D 19
    Document Type Test Method
    Product Note Reconfirmed 1997
    Publisher American Society for Testing and Materials
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    ASTM D 4411 : 2003 : R2014 : EDT 1 Standard Guide for Sampling Fluvial Sediment in Motion
    ASTM D 7100 : 2011 Standard Test Method for Hydraulic Conductivity Compatibility Testing of Soils with Aqueous Solutions
    ASTM D 7726 : 2011 : R2016 : EDT 1 Standard Guide for The Use of Various Turbidimeter Technologies for Measurement of Turbidity in Water
    ASTM D 7512 : 2009 : R2015 Standard Guide for Monitoring of Suspended-Sediment Concentration in Open Channel Flow Using Optical Instrumentation
    ASTM D 5907 : 2018 Standard Test Methods for Filterable Matter (Total Dissolved Solids) and Nonfilterable Matter (Total Suspended Solids) in Water
    ASTM D 7100 : 2011 : R2020 Standard Test Method for Hydraulic Conductivity Compatibility Testing of Soils with Aqueous Solutions
    ASTM D 4411 : 2003 : R2019 Standard Guide for Sampling Fluvial Sediment in Motion

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM D 1129 : 2013 : REDLINE Standard Terminology Relating to Water
    ASTM D 2777 : 2013 : REDLINE Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
    ASTM E 11 : 2017 : REDLINE Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves
    ASTM D 1888 : 1978 Methods of Test for Particulate and Dissolved Matter in Water (Withdrawn 1989)
    ASTM D 4410 : 2016 : REDLINE Terminology for Fluvial Sediment
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective