ASTM D 4492 : 2010
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Standard Test Method for Analysis of Benzene by Gas Chromatography (Withdrawn 2018)
Hardcopy , PDF
12-01-2018
English
15-03-2010
CONTAINED IN VOL. 06.04, 2017 Defines the determination of normally occurring trace impurities in, and the purity of, finished benzene by gas chromatography.
Committee |
D 16
|
DocumentType |
Test Method
|
Pages |
4
|
PublisherName |
American Society for Testing and Materials
|
Status |
Withdrawn
|
Supersedes |
1.1 This test method covers the determination of normally occurring trace impurities in, and the purity of, finished benzene by gas chromatography.
1.2 This test method is applicable for benzene purities of 99.80 weight % or higher.
1.3 The lower limit for detection for non-aromatic impurities is 50 mg/kg. The lower limit of detection for individual aromatic hydrocarbon impurities 10 mg/kg. The lower limit of detection for 1,4-dioxane is 5 mg/kg.
1.4 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding off method of Practice E29.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.
ASTM D 7185 : 2017 : REDLINE | Standard Specification for Low Toluene Low Dioxane (LTLD) Benzene |
ASTM UOP 555 : 2010 | Trace Impurities in Benzene by GC |
ASTM D 7504 : 2018 : REDLINE | Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number |
ASTM D 7124 : 2017 | Standard Specification for Benzene for Use with Zeolite Based Catalysts |
ASTM D 5871 : 2017 : REDLINE | Standard Specification for Benzene for Cyclohexane Feedstock |
ASTM D 7360 : 2016 : REDLINE | Standard Test Method for Analysis of Benzene by Gas Chromatography with External Calibration |
ASTM D 7124 : 2017 : REDLINE | Standard Specification for Benzene for Use with Zeolite Based Catalysts |
ASTM D 7185 : 2017 | Standard Specification for Low Toluene Low Dioxane (LTLD) Benzene |
ASTM D 2359 : 2018 : REV A | Standard Specification for Refined Benzene-535 |
ASTM D 7504 : 2018 | Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number |
ASTM D 7951 : 2018 | Standard Specification for Disproportionation (TDP) Toluene |
ASTM D 7360 : 2016 | Standard Test Method for Analysis of Benzene by Gas Chromatography with External Calibration (Withdrawn 2023) |
ASTM D 4734 : 2018 : REV A | Standard Specification for Refined Benzene-545 |
ASTM D 5871 : 2017 | Standard Specification for Benzene for Cyclohexane Feedstock |
ASTM E 260 : 1996 | Standard Practice for Packed Column Gas Chromatography |
ASTM D 852 : 2016 : REDLINE | Standard Test Method for Solidification Point of Benzene |
CFR 29(PT1910.1000 TO END) : 0 | LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR |
ASTM D 3437 : 2015 : REDLINE | Standard Practice for Sampling and Handling Liquid Cyclic Products |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.