• Shopping Cart
    There are no items in your cart

ASTM D 4519 : 2016 : REDLINE

Current

Current

The latest, up-to-date edition.

Standard Test Method for On-Line Determination of Anions and Carbon Dioxide in High Purity Water by Cation Exchange and Degassed Cation Conductivity

Available format(s)

PDF

Language(s)

English

Published date

01-06-2016

€67.30
Excluding VAT

CONTAINED IN VOL. 11.01, 2018 Defines hydrogen exchange and degassing by boiling and provides means for determining anions (such as Cl[-], SO[-4], NO[-3], and F[-]) at levels as low as 2 [mu]g/L (2 ppb) and carbon dioxide at the level of 0.01 to 10 mg/L (ppm) at 25 degrees C in high purity water and steam condensate by measuring electrical conductivity.

Committee
D 19
DocumentType
Redline
Pages
10
PublisherName
American Society for Testing and Materials
Status
Current

1.1This on-line test method includes hydrogen exchange and degassing by heating or gas stripping and provides means for determining anions (such as Cl, SO4, NO3, and F) at levels as low as 2 μg/L (2 ppb) and carbon dioxide at the level of 0.01 to 10 mg/L (ppm) at 25°C in high purity water and in steam and water samples in power plants by measuring electrical conductivity.

1.2The conductivity of all anions (except OH) is determined and not the conductivity of an individual anion if more than one is present. If only one anion is present (such as Cl or SO4—−), reference to Section 4, Table 1 and Table 2 or Figs. 1-3 provides the chloride or sulfate and CO2 concentration.

1.3This test method has been improved in accuracy by using a modern microprocessor instrument for conductivity and temperature measurement and appropriate temperature compensation algorithms for compensation, by using final sample cooling to 25°C, or both.

1.4The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM D 6317 : 2015 : REDLINE Standard Test Method for Low Level Determination of Total Carbon, Inorganic Carbon and Organic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
ASTM D 5391 : 2014 : REDLINE Standard Test Method for Electrical Conductivity and Resistivity of a Flowing High Purity Water Sample (Withdrawn 2023)
ASTM D 6504 : 2011 Standard Practice for On-Line Determination of Cation Conductivity in High Purity Water
ASTM D 6504 : 2011 : R2016 : EDT 1 Standard Practice for On-Line Determination of Cation Conductivity in High Purity Water
API 538 : 2015 INDUSTRIAL FIRED BOILERS FOR GENERAL REFINERY AND PETROCHEMICAL SERVICE
ASTM D 5997 : 2015 : REDLINE Standard Test Method for On-Line Monitoring of Total Carbon, Inorganic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
ASTM D 1125 : 2014 : REDLINE Standard Test Methods for Electrical Conductivity and Resistivity of Water (Withdrawn 2023)

ASTM D 1129 : 2013 : REDLINE Standard Terminology Relating to Water
ASTM D 2777 : 2013 : REDLINE Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
ASTM D 1125 : 2014 : REDLINE Standard Test Methods for Electrical Conductivity and Resistivity of Water (Withdrawn 2023)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.