ASTM D 4657 : 1992 : R1998
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Standard Test Method for Polynuclear Aromatic Hydrocarbons in Water (Withdrawn 2005)
Hardcopy , PDF
08-02-2005
English
10-07-1998
CONTAINED IN VOL. 11.02, 2001 Determines certain poly nuclear aromatic hydrocarbons (PAHs) in water and wastewater.
Committee |
D 19
|
DocumentType |
Test Method
|
Pages |
9
|
PublisherName |
American Society for Testing and Materials
|
Status |
Withdrawn
|
1.1 This test method covers the determination of certain polynuclear aromatic hydrocarbons (PAHs) in water and wastewater. The following compounds may be determined by this test method: acenaphthene, acenaphthylene, anthracene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(ghi)perylene, benzo(k)fluoranthene, chrysene, dibenzo(ah)anthracene, fluoranthene, fluorene, indeno(1,2,3-cd)pyrene, naphthalene, phenathrene, and pyrene. Additional PAHs may also be determined; however, the analyst should demonstrate that the test method is in fact applicable to the specific PAH(s) of interest before applying it to sample analysis. This test method has high sensitivity for the compounds of interest. It is limited to use by analysts familiar with high-performance liquid chromatography (HPLC) or working under close supervision of such persons.
1.2 This test method is applicable to the determination of the compounds in 1.1 in water and wastewater. This test method has been successfully used with distilled water, tap water, surface water, and the following wastewaters: effluent from an oil refinery, blast furnace, and combined coke oven and blast furnace. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices. It presupposes a high expectation of finding the specific compounds of interest. If the user is attempting to screen samples for any or all of the compounds above, component identities should be verified by using two different types of reverse phase HPLC columns, both ultraviolet and fluorescence detection, or gas chromatography/mass spectrometry-spectroscopy screening procedures, or both.
1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 9.
ASTM D 5412 : 1993 : R2011 : EDT 1 | Standard Test Method for Quantification of Complex Polycyclic Aromatic Hydrocarbon Mixtures or Petroleum Oils in Water |
ASTM D 5412 : 1993 : R2005 | Standard Test Method for Quantification of Complex Polycyclic Aromatic Hydrocarbon Mixtures or Petroleum Oils in Water |
ASTM D 6187 : 1997 : R2010 | Standard Practice for Cone Penetrometer Technology Characterization of Petroleum Contaminated Sites with Nitrogen Laser-Induced Fluorescence (Withdrawn 2019) |
ASTM D 6187 : 1997 : R2003 | Standard Practice for Cone Penetrometer Technology Characterization of Petroleum Contaminated Sites with Nitrogen Laser-Induced Fluorescence |
ASTM D 5412 : 1993 : R2000 | Standard Test Method for Quantification of Complex Polycyclic Aromatic Hydrocarbon Mixtures or Petroleum Oils in Water |
ASTM D 3694 : 1996 | Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents |
ASTM D 6187 : 1997 | Standard Practice for Cone Penetrometer Technology Characterization of Petroleum Contaminated Sites with Nitrogen Laser-Induced Fluorescence |
ASTM D 5412 : 1993 : R2017 : EDT 1 | Standard Test Method for Quantification of Complex Polycyclic Aromatic Hydrocarbon Mixtures or Petroleum Oils in Water |
ASTM D 5412 : 1993 | TEST METHOD FOR QUANTIFICATION OF COMPLEX POLYCYCLIC AROMATIC HYDROCARBON MIXTURES OR PETROLEUM OILS IN WATER |
ASTM D 3694 : 1996 : R2011 | Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents |
ASTM D 5412 : 1993 : R2011 | Standard Test Method for Quantification of Complex Polycyclic Aromatic Hydrocarbon Mixtures or Petroleum Oils in Water |
ASTM D 3694 : 1996 : R2004 | Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents |
ASTM D 3694 : 1996 : R2017 | Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents |
ASTM D 1129 : 2013 : REDLINE | Standard Terminology Relating to Water |
ASTM D 1253 : 2014 : REDLINE | Standard Test Method for Residual Chlorine in Water |
ASTM D 1192 : 1998 | Standard Guide for Equipment for Sampling Water and Steam in Closed Conduits (Withdrawn 2003) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.