• Shopping Cart
    There are no items in your cart

ASTM D 5011 : 1992 : R2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practices for Calibration of Ozone Monitors Using Transfer Standards

Available format(s)

Hardcopy , PDF

Superseded date

18-10-2024

Superseded by

ASTM D 5011 : 2017

Language(s)

English

Published date

01-03-2009

€96.91
Excluding VAT

Committee
D 22
DocumentType
Standard Practice
Pages
29
ProductNote
Reconfirmed 2009
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 These practices describe means for calibrating ambient, workplace or indoor ozone monitors, using transfer standards.

1.2 These practices describe five types of transfer standards:

(A) Analytical instruments

(B) Boric acid potassium iodide (BAKI) manual analytical procedure

(C) Gas phase titration with excess nitric oxide

(D) Gas phase titration with excess ozone

(E) Ozone generator device.

1.3 These practices describe procedures to establish the authority of transfer standards: qualification, certification, and periodic recertification.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 8 for specific precautionary statements.

ASTM D 7439 : 2014 Standard Test Method for Determination of Elements in Airborne Particulate Matter by Inductively Coupled Plasma–Mass Spectrometry
ASTM D 1356 : 2017 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 5149 : 2002 : R2016 Standard Test Method for Ozone in the Atmosphere: Continuous Measurement by Ethylene Chemiluminescence
ASTM D 5156 : 2002 : R2016 Standard Test Methods for Continuous Measurement of Ozone in Ambient, Workplace, and Indoor Atmospheres (Ultraviolet Absorption)
ASTM D 5110 : 1998 : R2017 Standard Practice for Calibration of Ozone Monitors and Certification of Ozone Transfer Standards Using Ultraviolet Photometry

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.