• There are no items in your cart

ASTM D 5017 : 2017 : REDLINE

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Determination of Linear Low Density Polyethylene (LLDPE) Composition by Carbon-13 Nuclear Magnetic Resonance

Available format(s)

PDF

Superseded date

30-09-2024

Language(s)

English

Published date

01-03-2017

€67.30
Excluding VAT

CONTAINED IN VOL. 08.03, 2017 Describes the molar composition of copolymers prepared from ethylene (ethene) and a second alkene-1 monomer.

Committee
D 20
DocumentType
Redline
Pages
8
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1This test method determines the molar composition of copolymers prepared from ethylene (ethene) and a second alkene-1 monomer. This second monomer can include propene, butene-1, hexene-1, octene-1, and 4-methylpentene-1.

1.2Calculations of this test method are valid for products containing units EEXEE, EXEXE, EXXE, EXXXE, and of course EEE where E equals ethene and X equals alkene-1. Copolymers containing a considerable number of alkene-1 blocks (such as, longer blocks than XXX) are outside the scope of this test method.

1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 8 for a specific hazard statement.

Note 1:There is no known ISO equivalent to this standard.

VDI 3822 Blatt 2.1.8:2012-01 Failure analysis - Defects of thermoplastic products made of plastics caused by weather-induced stress
VDI 3822 Blatt 2.1.10:2012-01 Failure analysis - Significant instrumental analysis methods for failure analysis of products made of plastics

ASTM E 2977 : 2015 : REDLINE Standard Practice for Measuring and Reporting Performance of Fourier-Transform Nuclear Magnetic Resonance (FT-NMR) Spectrometers for Liquid Samples
ASTM E 177 : 2014 : REDLINE Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods
IEEE/ASTM SI_10-2010 American National Standard for Metric Practice

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.