• ASTM D 5017 : 2017 : REDLINE

    Current The latest, up-to-date edition.

    Standard Test Method for Determination of Linear Low Density Polyethylene (LLDPE) Composition by Carbon-13 Nuclear Magnetic Resonance

    Available format(s):  PDF

    Language(s):  English

    Published date:  27-03-2017

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 08.03, 2017 Describes the molar composition of copolymers prepared from ethylene (ethene) and a second alkene-1 monomer.

    Scope - (Show below) - (Hide below)

    1.1This test method determines the molar composition of copolymers prepared from ethylene (ethene) and a second alkene-1 monomer. This second monomer can include propene, butene-1, hexene-1, octene-1, and 4-methylpentene-1.

    1.2Calculations of this test method are valid for products containing units EEXEE, EXEXE, EXXE, EXXXE, and of course EEE where E equals ethene and X equals alkene-1. Copolymers containing a considerable number of alkene-1 blocks (such as, longer blocks than XXX) are outside the scope of this test method.

    1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 8 for a specific hazard statement.

    Note 1:There is no known ISO equivalent to this standard.

    General Product Information - (Show below) - (Hide below)

    Committee D 20
    Document Type Redline
    Publisher American Society for Testing and Materials
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    VDI 3822 Blatt 2.1.8:2012-01 Failure analysis - Defects of thermoplastic products made of plastics caused by weather-induced stress
    VDI 3822 Blatt 2.1.10:2012-01 Failure analysis - Significant instrumental analysis methods for failure analysis of products made of plastics

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM E 2977 : 2015 : REDLINE Standard Practice for Measuring and Reporting Performance of Fourier-Transform Nuclear Magnetic Resonance (FT-NMR) Spectrometers for Liquid Samples
    ASTM E 177 : 2014 : REDLINE Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods
    IEEE/ASTM SI_10-2010 American National Standard for Metric Practice
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective