Standard Guide for On-Line Monitoring of Total Organic Carbon in Water by Oxidation and Detection of Resulting Carbon Dioxide

Available format(s)

PDF

Language(s)

English

Published date

27-04-2015

€67.30
Excluding VAT

CONTAINED IN VOL. 11.01, 2017 Defines the selection, establishment, and application of monitoring systems for carbon and carbon compounds by continual sampling or continuous flow-through, automatic analysis, and recording or otherwise signaling of output data.

Committee
D 19
DocumentType
Redline
Pages
8
PublisherName
American Society for Testing and Materials
Status
Current

1.1This guide covers the selection, establishment, and application of monitoring systems for carbon and carbon compounds by on-line, automatic analysis, and recording or otherwise signaling of output data. The system chosen will depend on the purpose for which it is intended (for example, regulatory compliance, process monitoring, or to alert the user to adverse trends) and on the type of water to be monitored (low purity or high purity, with or without suspended particulates, purgeable organics, or inorganic carbon). If it is to be used for regulatory compliance, the test method published or referenced in the regulations should be used in conjunction with this guide and other ASTM test methods. This guide covers carbon concentrations of 0.05 µg/L to 50 000 mg/L. Low end sensitivity and quantitative results may vary among instruments. This guide covers the on-line measurement techniques listed in Table 1. Additional laboratory test methods are available: Test Methods D4129, D4839, D5904, D6317, and D7573.

(A)Consult manufacturer for specific range of measurement.

1.2The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.

ASTM D 5906 : 2002 : R2007 Standard Guide for Measuring Horizontal Positioning During Measurements of Surface Water Depths
ASTM D 5196 : 2006 : R2018 Standard Guide for Bio-Applications Grade Water
ASTM D 1193 : 2006 : R2018 Standard Specification for Reagent Water
ASTM D 5906 : 2002 Standard Guide for Measuring Horizontal Positioning During Measurements of Surface Water Depths
ASTM D 5196 : 2006 Standard Guide for Bio-Applications Grade Water
ASTM D 6908 : 2006 : R2010 Standard Practice for Integrity Testing of Water Filtration Membrane Systems
ASTM D 5906 : 2002 : R2013 Standard Guide for Measuring Horizontal Positioning During Measurements of Surface Water Depths
ASTM D 6908 : 2006 Standard Practice for Integrity Testing of Water Filtration Membrane Systems
ASTM D 1193 : 2006 : R2011 Standard Specification for Reagent Water
ASTM D 1193 : 2006 Standard Specification for Reagent Water
ASTM D 5196 : 2006 : R2013 Standard Guide for Bio-Applications Grade Water
ASTM D 6908 : 2006 : R2017 Standard Practice for Integrity Testing of Water Filtration Membrane Systems
ASTM E 2656 : 2016 : REDLINE Standard Practice for Real-time Release Testing of Pharmaceutical Water for the Total Organic Carbon Attribute

ASTM D 6317 : 2015 : REDLINE Standard Test Method for Low Level Determination of Total Carbon, Inorganic Carbon and Organic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
ASTM D 1129 : 2013 : REDLINE Standard Terminology Relating to Water
ASTM D 2777 : 2013 : REDLINE Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
EN 1484:1997 Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
ASTM D 4453 : 2017 : REDLINE Standard Practice for Handling of High Purity Water Samples
ASTM D 5997 : 2015 : REDLINE Standard Test Method for On-Line Monitoring of Total Carbon, Inorganic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.