• Shopping Cart
    There are no items in your cart

ASTM D 5175 : 1991 : R2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Organohalide Pesticides and Polychlorinated Biphenyls in Water by Microextraction and Gas Chromatography

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

10-01-2003

€74.48
Excluding VAT

CONTAINED IN VOL. 11.02, 2018 Pertains to the determination of a number of analytes (listed in the document) in drinking water during intermediate stages of treatment, finished drinking water, and the raw source water.

Committee
D 19
DocumentType
Test Method
Pages
12
ProductNote
Reconfirmed 2003
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This test method (1,2,3) is applicable to the determination of the following analytes in finished drinking water, drinking water during intermediate stages of treatment, and the raw source water:

AnalyteChemical Abstract Service Registry Number
Alachlor5972-60-8
Aldrin309-00-2
Chlordane57-74-9
Dieldrin60-57-1
Endrin72-20-8
Heptachlor76-44-8
Heptachlor Epoxide1024-57-3
Hexachlorobenzene118-74-1
Lindane58-89-9
Methoxychlor72-43-5
Toxaphene8001-35-2
Aroclor 101612674-11-2
Aroclor 122111104-28-2
Aroclor 123211141-16-5
Aroclor 124253469-21-9
Aroclor 124812672-29-6
Aroclor 125411097-69-1
Aroclor 126011096-82-5

Numbering system of CAS Registry Services, P.O. Box 3343, Columbus, OH 43210-0334.

Aroclor is a registered trademark of Monsanto Co.

1.2 Detection limits for most test method analytes are less than 1 μg/L. Actual detection limits are highly dependent on the characteristics of the sample matrix and the gas chromatography system. contains the applicable concentration range for the precision and bias statements. Only Aroclor 1016 and 1254 were included in the interlaboratory test used to derive the precision and bias statements. Data for other PCB products are likely to be similar.

1.3 Chlordane, toxaphene, and Aroclor products (polychlorinated biphenyls) are multicomponent materials. Precision and bias statements reflect recovery of these materials dosed into water samples. The precision and bias statements may not apply to environmentally altered materials or to samples containing complex mixtures of polychlorinated biphenyls (PCBs) and organochlorine pesticides.

1.4 For compounds other than those listed in or for other sample sources, the analyst must demonstrate the applicability of this test method by collecting precision and bias data on spiked samples (groundwater, tap water) (4)and provide qualitative confirmation of results by gas chromatography/mass spectrometry (GC/MS) (5) or by GC analysis using dissimilar columns.

1.5 This test method is restricted to use by or under the supervision of analysts experienced in the use of GC and in the interpretation of gas chromatograms. Each analyst must demonstrate the ability to generate acceptable results using the procedure described in Section 13.

1.6 Analytes that are not separated chromatographically, (analytes that have very similar retention times) cannot be individually identified and measured in the same calibration mixture or water sample unless an alternative technique for identification and quantitation exists (see section 13.4).

1.7 When this test method is used to analyze unfamiliar samples for any or all of the analytes listed in , analyte identifications and concentrations should be confirmed by at least one additional technique.

1.8 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only.

1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.

ASTM D 3694 : 1996 : R2017 Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents
ASTM D 5241 : 1992 : R2017 Standard Practice for Micro-Extraction of Water for Analysis of Volatile and Semi-Volatile Organic Compounds in Water

ASTM D 1129 : 2013 : REDLINE Standard Terminology Relating to Water
CFR 29(PT1910.1000 TO END) : 0 LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR