• There are no items in your cart

ASTM D 5314 : 1992 : R2006

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Standard Guide for Soil Gas Monitoring in the Vadose Zone (Withdrawn 2015)

Available format(s)

Hardcopy , PDF

Withdrawn date

02-07-2015

Language(s)

English

Published date

01-07-2006

€96.91
Excluding VAT

Committee
D 18
DocumentType
Guide
Pages
37
ProductNote
Reconfirmed 2006
PublisherName
American Society for Testing and Materials
Status
Withdrawn
Supersedes

1.1 This guide covers information pertaining to a broad spectrum of practices and applications of soil atmosphere sampling, including sample recovery and handling, sample analysis, data interpretation, and data reporting. This guide can increase the awareness of soil gas monitoring practitioners concerning important aspects of the behavior of the soil-water-gas-contaminant system in which this monitoring is performed, as well as inform them of the variety of available techniques of each aspect of the practice. Appropriate applications of soil gas monitoring are identified, as are the purposes of the various applications. Emphasis is placed on soil gas contaminant determinations in certain application examples.

1.2 This guide suggests a variety of approaches useful to successfully monitor vadose zone contaminants with instructions that offer direction to those who generate and use soil gas data.

1.3 This guide does not recommend a standard practice to follow in all cases nor does it recommend definite courses of action. The success of any one soil gas monitoring methodology is strongly dependent upon the environment in which it is applied.

1.4 Concerns of practitioner liability or protection from or release from such liability, or both, are not addressed by this guide.

1.5 This guide is organized into the following sections and subsections that address specific segments of the practice of monitoring soil gas:

Section
4Summary of Practice
4.1Basic principles, including partitioning theory, migration and emplacement processes, and contaminant degradation
4.7Summary Procedure
5Significance and Use
6Approach and Procedure
6.1Sampling Methodology
6.5Sample Handling and Transport
6.6Analysis of Soil Gas Samples
6.7Data Interpretation
7Reporting

1.6 This guide does not purport to set standard levels of acceptable risk. Use of this guide for purposes of risk assessment is wholly the responsibility of the user.

1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.9 This guide offers an organized collection of information or a series of options and does not recommend a specific course of action. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this guide may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project's many unique aspects. The word Standard in the title of this document means only that the document has been approved through the ASTM consensus process.

ASTM D 7648/D7648M : 2018 Standard Practice for Active Soil Gas Sampling for Direct Push or Manual-Driven Hand-Sampling Equipment (Withdrawn 2024)
ASTM D 6009 : 2012 Standard Guide for Sampling Waste Piles
ASTM D 6001 : 2005 : R2012 Standard Guide for Direct-Push Groundwater Sampling for Environmental Site Characterization
ASTM D 7758 : 2017 Standard Practice for Passive Soil Gas Sampling in the Vadose Zone for Source Identification, Spatial Variability Assessment, Monitoring, and Vapor Intrusion Evaluations
ASTM D 6232 : 2016 Standard Guide for Selection of Sampling Equipment for Waste and Contaminated Media Data Collection Activities

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.