• ASTM D 5466 : 2015 : REDLINE

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Standard Test Method for Determination of Volatile Organic Compounds in Atmospheres (Canister Sampling Methodology)

    Available format(s):  PDF

    Superseded date:  15-09-2021

    Language(s):  English

    Published date:  01-12-2015

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 11.03, 2016 Specifies a procedure for sampling and analysis of volatile organic compounds (VOCs) in ambient, indoor, or workplace atmospheres.

    Scope - (Show below) - (Hide below)

    1.1This standard describes a procedure for sampling and analysis of selected volatile organic compounds (VOCs) in ambient, indoor, and workplace atmospheres. The test method is based on the collection of whole air samples in stainless steel canisters with specially treated (passivated) interior surfaces. For sample analysis, a portion of the sample is subsequently removed from the canister and the collected VOCs are selectively concentrated by adsorption or condensation onto a trap, subsequently released by thermal desorption, separated by gas chromatography, and measured by a mass spectrometric detector or other detector(s). This test method describes procedures for sampling into canisters to final pressures both above and below atmospheric pressure (respectively referred to as pressurized and subatmospheric pressure sampling).2

    1.2This test method is applicable to specific VOCs that have been determined to be stable when stored in canisters. Numerous compounds, many of which are chlorinated VOCs, have been successfully tested for storage stability in pressurized canisters (1-4).3 Documentation is also available demonstrating stability of VOCs in subatmospheric pressure canisters. Information on storage stability is available for many polar compounds as well (5-7).

    1.3The procedure for collecting the sample involves the use of inlet lines, air filters, flow rate regulators for obtaining time-integrated samples, and in the case of pressurized samples, an air pump. Typical long-term fixed location canister samplers have been designed to automatically start and stop the sample collection process using electronically actuated valves and timers (8-10). Temporary or short-term canister samplers may require the user to manually start and stop sample collection. A weatherproof shelter may be required if the sampler is used outdoors. For the purposes of this test method, refer to Practice D1357 for practices and planning ambient sampling events.

    1.4The organic compounds that have been successfully measured at single-digit parts-per-billion by volume (ppbv) levels with this test method are listed in Table 1. The test method is applicable to VOC concentrations ranging from the detection limit to approximately 300 ppbv. Above this concentration, smaller sample aliquots of sample gas may be analyzed or samples can be diluted with dry ultra-high-purity nitrogen or air.

    1.5The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

    1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Safety practices should be part of the user's SOP manual.

    General Product Information - (Show below) - (Hide below)

    Committee D 22
    Document Type Redline
    Publisher American Society for Testing and Materials
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS ISO 18562-3:2017 Biocompatibility evaluation of breathing gas pathways in healthcare applications Tests for emissions of volatile organic compounds (VOCs)
    DD ISO/TS 14687-2:2008 Hydrogen fuel. Product specification Proton exchange membrane (PEM) fuel cell applications for road vehicles
    09/30203808 DC : 0 BS EN ISO 80601-2-12 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS
    ASTM D 5953M : 2016 : REDLINE Standard Test Method for Determination of Non-methane Organic Compounds (NMOC) in Ambient Air Using Cryogenic Preconcentration and Direct Flame Ionization Detection
    ASTM D 1356 : 2017 : REDLINE Standard Terminology Relating to Sampling and Analysis of Atmospheres
    ASTM D 6399 : 2010-07 GUIDE FOR SELECTING INSTRUMENTS AND METHODS FOR MEASURING AIR QUALITY IN AIRCRAFT CABINS
    ASTM D 6177 : 2014 : REDLINE Standard Practice for Determining Emission Profiles of Volatile Organic Chemicals Emitted from Bedding Sets
    ASTM D 7911 : 2014 Standard Guide for Using Reference Material to Characterize Measurement Bias Associated with Volatile Organic Compound Emission Chamber Test
    ASTM D 7297 : 2014 : REDLINE Standard Practice for Evaluating Residential Indoor Air Quality Concerns
    ASHRAE HDBK REFRIGERATION : 2014 ASHRAE HANDBOOK - REFRIGERATION
    15/30278530 DC : 0 BS ISO 18562-1 - BIOCOMPATIBILITY EVALUATION OF BREATHING GAS PATHWAYS IN HEALTHCARE APPLICATIONS - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS
    15/30278537 DC : 0 BS ISO 18562-3 - BIOCOMPATIBILITY EVALUATION OF BREATHING GAS PATHWAYS IN HEALTHCARE APPLICATIONS - PART 3: TESTS FOR EMISSIONS OF VOLATILE ORGANIC COMPOUNDS (VOCS)
    ASTM D 6803 : 2013 : REDLINE Standard Practice for Testing and Sampling of Volatile Organic Compounds (Including Carbonyl Compounds) Emitted from Paint Using Small Environmental Chambers
    ASHRAE GUIDELINE 28 : 2012 AIR QUALITY WITHIN COMMERCIAL AIRCRAFT
    ISO/TS 14687-2:2008 Hydrogen fuel Product specification Part 2: Proton exchange membrane (PEM) fuel cell applications for road vehicles
    SAE AIR 4766/2 : 2011 AIRBORNE CHEMICALS IN AIRCRAFT CABINS
    ISO 18562-3:2017 Biocompatibility evaluation of breathing gas pathways in healthcare applications — Part 3: Tests for emissions of volatile organic compounds (VOCs)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective