• There are no items in your cart

ASTM D 5812 : 1996

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Determination of Organochlorine Pesticides in Water by Capillary Column Gas Chromatography

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

31-12-2010

€74.48
Excluding VAT

CONTAINED IN VOL. 11.02, 2009 Covers the capillary gas chromatographic determination of various organochlorine pesticides, including some of their degradation products and related compounds in finished drinking water. This method is not limited to this particular aqueous matrix; however, its applicability to other aqueous matrices must be determined.

Committee
D 19
DevelopmentNote
Supersedes ASTM D 3086 (12/2001)
DocumentType
Test Method
Pages
12
ProductNote
Reconfirmed 1996
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 This test method covers the capillary gas chromatographic determination of various organochlorine pesticides, including some of their degradation products and related compounds in finished drinking water. This test method is not limited to this particular aqueous matrix; however, its applicability to other aqueous matrices must be determined. The tested compounds include the following:

Chemical Abstract Pesticide Service Registry Number A Aldrin 309-00-2 [alpha]-BHC 319-84-6 [beta]-BHC 319-85-7 [gamma]-BHC 319-86-8 [delta]-BHC 58-89-9 [alpha]-Chlordane 5103-71-9 [gamma]-Chlordane 5103-74-2 Chlorobenzilate 501-15-6 Chloroneb 2675-77-6 Chlorothalonil 2921-88-2 DCPA 1897-45-6 4,4'-DDD 72-54-8 4,4'-DDE 72-55-9 4,4'-DDT 50-29-3 Dieldrin 60-57-1 Endosulfan I 959-98-8 Endosulfan II 33213-65-9 Endosulfan sulfate 1031-0708 Endrin 72-20-8 Endrin aldehyde 7421-93-4 Etridiazole 2593-15-9 Heptachlor 76-44-8 Heptachlor epoxide 1024-57-3 Hexachlorobenzene 118-74-1 Methoxychlor 72-43-5 cis-Permethrin 52645-53-1 trans-Permethrin 52645-53-1 Propachlor 1918-16-7 Trifluralin 1582-09-8 A Numbering system of CAS Registry Services, P.O. Box 3343, Columbus, OH 43210-0334.

1.2 Tables 1 and 1 list the applicable concentration ranges and precision and bias statements for this test method. The applicability of this test method to other compounds must be demonstrated.

1.3 The extraction conditions of this test method are comparable to Test Method D3534, which determines commercial polychlorinated biphenyl (PCB) mixtures (Aroclors). The extract derived from this procedure may be analyzed for these constituents by using the gas chromatography (GC) conditions prescribed in either Test Method D3534 (packed column) or Test Method D5175 (capillary column). Although the columns used in this test method may be adequate for analyzing PCBs, no data were collected for any multi-congener constituents during methods development.

1.4 This test method is restricted to use by or under the supervision of analysts experienced in the use of GC and interpretation of gas chromatograms. Each analyst must demonstrate the ability to generate acceptable results using the procedures described in Section 12.

1.5 Analytes that are not separated chromatographically by either the primary or secondary chromatographic columns (for example, analytes having very similar retention times) cannot be identified and measured individually in the same calibration mixture or water sample unless an alternative technique for identification and quantitation exists (see 7.9 and 13.4).

1.6 When this test method is used to analyze unfamiliar samples for any or all of the analytes listed in 1.1, analyte identifications and concentrations should be confirmed by at least one additional technique.

1.7 The values stated in SI units are to be regarded as the standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 9.

ASTM D 3694 : 1996 : R2017 Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents

ASTM D 1129 : 2013 : REDLINE Standard Terminology Relating to Water
ASTM D 2777 : 2013 : REDLINE Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
ASTM E 260 : 1996 Standard Practice for Packed Column Gas Chromatography
ASTM D 1192 : 1998 Standard Guide for Equipment for Sampling Water and Steam in Closed Conduits (Withdrawn 2003)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.