• Shopping Cart
    There are no items in your cart

ASTM D 5882 : 2016 : REDLINE

Current

Current

The latest, up-to-date edition.

Standard Test Method for Low Strain Impact Integrity Testing of Deep Foundations

Available format(s)

PDF

Language(s)

English

Published date

01-07-2016

€67.30
Excluding VAT

CONTAINED IN VOL. 04.09, 2016 Defines the procedure for determining the integrity of individual vertical or inclined piles by measuring and analyzing the velocity (required) and force (optional) response of the pile induced by an (hand held hammer or other similar type) impact device applied axially and perpendicularly to the pile head surface.

Committee
D 18
DocumentType
Redline
Pages
7
PublisherName
American Society for Testing and Materials
Status
Current

1.1This test method covers the procedure for determining the integrity of individual vertical or inclined piles by measuring and analyzing the velocity (required) and force (optional) response of the pile induced by an (hand held hammer or other similar type) impact device usually applied axially and perpendicularly to the pile head surface. This test method is applicable to long structural elements that function in a manner similar to any deep foundation units (such as driven piles, augeured piles, or drilled shafts), regardless of their method of installation provided that they are receptive to low strain impact testing.

1.2This standard provides minimum requirements for low strain impact testing of piles. Plans, specifications, and/or provisions prepared by a qualified engineer, and approved by the agency requiring the test(s), may provide additional requirements and procedures as needed to satisfy the objectives of a particular test program.

1.3The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

1.4The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026.

1.6The method used to specify how data are collected, calculated, or recorded in this standard is not directly related to the accuracy to which the data can be applied in design or other uses, or both. How one applies the results obtained using this standard is beyond its scope.

1.7This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Note 1:he quality of the result produced by this test method is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/ inspection/etc. Users of this test method are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors.

ASTM D 8169/D8169M : 2018 Standard Test Methods for Deep Foundations Under Bi-Directional Static Axial Compressive Load
ASTM D 1143/D1143M : 2007 : R2013 Standard Test Methods for Deep Foundations Under Static Axial Compressive Load
ASTM D 3966/D3966M : 2007 : R2013 : EDT 1 Standard Test Methods for Deep Foundations Under Lateral Load
PIP STS02465 : 2012 AUGERED CAST-IN-PLACE PILES INSTALLATION SPECIFICATION
ASTM D 1143/D1143M : 2007 Standard Test Methods for Deep Foundations Under Static Axial Compressive Load
AASHTO TP 104 : 2013(R2015) METHOD OF TEST FOR RAPID AXIAL COMPRESSIVE LOAD TESTING OF DEEP FOUNDATION UNITS
ACI 543R : 2012 GUIDE TO DESIGN, MANUFACTURE, AND INSTALLATION OF CONCRETE PILES
AASHTO TP 104:2013 Standard Method of Test for Rapid Axial Compressive Load Testing of Deep Foundation Units
ASTM D 1143/D1143M : 2007 : R2013 : EDT 1 Standard Test Methods for Deep Foundations Under Static Axial Compressive Load
ASTM D 6760 : 2016 : REDLINE Standard Test Method for Integrity Testing of Concrete Deep Foundations by Ultrasonic Crosshole Testing
ASTM D 1143/D1143M : 2007 : EDT 1 Standard Test Methods for Deep Foundations Under Static Axial Compressive Load
ASTM D 3689/D3689M : 2007 : R2013 : EDT 1 Standard Test Methods for Deep Foundations Under Static Axial Tensile Load
ASTM C 1740 : 2016 : REDLINE Standard Practice for Evaluating the Condition of Concrete Plates Using the Impulse-Response Method
PIP STE02465 : 2012 AUGERED CAST-IN-PLACE PILES DESIGN GUIDE

ASTM D 3740 : 2012-06 PRACTICE FOR MINIMUM REQUIREMENTS FOR AGENCIES ENGAGED IN TESTING AND/OR INSPECTION OF SOIL AND ROCK AS USED IN ENGINEERING DESIGN AND CONSTRUCTION
ASTM D 7949 : 2014 Standard Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations (Withdrawn 2023)
ASTM D 6026 : 2013 : REDLINE Standard Practice for Using Significant Digits in Geotechnical Data
ASTM D 6760 : 2016 : REDLINE Standard Test Method for Integrity Testing of Concrete Deep Foundations by Ultrasonic Crosshole Testing
ASTM D 653 : 2014 : REDLINE Standard Terminology Relating to Soil, Rock, and Contained Fluids

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.