ASTM D 5955 : 1996

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Methods for Estimating Contribution of Environmental Tobacco Smoke to Respirable Suspended Particles Based on UVPM and FPM

Superseded date

11-11-2014

Superseded by

ASTM D 5955 : 2002

Published date

10-05-1996

Sorry this product is not available in your region.

Committee
D 22
DocumentType
Test Method
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 These test methods pertain to the sampling/analysis of respirable suspended particles (RSP) and the estimation of the RSP fraction attributable to environmental tobacco smoke. These test methods are based on collection of total RSP on a membrane filter, extracting the collected material in methanol, and measuring total ultraviolet absorbance or fluorescence, or both, of this extract. The corresponding methods of estimation are termed ultraviolet particulate matter (UVPM) and fluorescent particulate matter (FPM), respectively.

1.2 The sampling components consist of a preweighed, 1.0-µm pore size polytetrafluoroethylene (PTFE) membrane filter in a filter cassette connected to the inlet end to a particle size separating device and, on the outlet end, to a sampling pump. These test methods are applicable to personal and area sampling.

1.3 These test methods are limited in sample duration only by the capacity of the membrane filter (about 2000 µg). These test methods have been evaluated up to a 24-h sample duration with a minimum sample duration of at least 1 h.

1.4 Limits of detection (LOD) and limit of quantitation (LOQ) for the UVPM test method at a sampling rate of 2 L/min are, respectively, 2.5 µg/m3 and 8.3 µg/m3 for a 1-h sample duration and 0.3 µg/m3 and 1.0 µg/m3 for an 8-h sample duration. the LOD and LOQ for the FPM test method at a sampling rate of 2 L/min are, respectively, 1.4 µg/m3 and 4.7 µg/m3 for a 1-h sample duration and 0.2 µg/m3 and 0.6 µg/m3 for an 8-h sample duration

1.5 The values stated in SI units are to be regarded as standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary information is given in 13.6.

ASTM D 7297 : 2014 Standard Practice for Evaluating Residential Indoor Air Quality Concerns
ASTM D 6271 : 2010 : R2016 Standard Test Method for Estimating Contribution of Environmental Tobacco Smoke to Respirable Suspended Particles Based on Solanesol (Withdrawn 2022)