• Shopping Cart
    There are no items in your cart

ASTM D 6091 : 2007 : R2014

Current

Current

The latest, up-to-date edition.

Standard Practice for 99 %/95 % Interlaboratory Detection Estimate (IDE) for Analytical Methods with Negligible Calibration Error (Withdrawn 2023)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

25-02-2014

€74.48
Excluding VAT

CONTAINED IN VOL. 11.01, 2017 Establishes a standard for computing a 99%/95% Interlaboratory Detection Estimate (IDE) and provides guidance concerning the appropriate use and application.

Committee
D 19
DocumentType
Standard Practice
Pages
13
ProductNote
Reconfirmed 2014
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

1.1This practice establishes a standard for computing a 99 %/95 % Interlaboratory Detection Estimate (IDE) and provides guidance concerning the appropriate use and application. The calculations involved in this practice can be performed with DQCALC, Microsoft Excel-based software available from ASTM.2

1.2The IDE is computed to be the lowest concentration at which there is 90 % confidence that a single measurement from a laboratory selected from the population of qualified laboratories represented in an interlaboratory study will have a true detection probability of at least 95 % and a true nondetection probability of at least 99 % (when measuring a blank sample).

1.3The fundamental assumption of the collaborative study is that the media tested, the concentrations tested, and the protocol followed in the study provide a representative and fair evaluation of the scope and applicability of the test method as written. When properly applied, the IDE procedure ensures that the 99 %/95 % IDE has the following properties:

1.3.1Routinely Achievable IDE Value—Most laboratories are able to attain the IDE detection performance in routine analyses, using a standard measurement system, at reasonable cost. This property is needed for a detection limit to be practically feasible. Representative laboratories must be included in the data to calculate the IDE.

1.3.2Routine Sources of Error Accounted For—The IDE should realistically include sources of bias and variation which are common to the measurement process. These sources include, but are not limited to: intrinsic instrument noise, some typical amount of carryover error, plus differences in laboratories, analysts, sample preparation, and instruments.

1.3.3Avoidable Sources of Error Excluded—The IDE should realistically exclude avoidable sources of bias and variation, that is, those which can reasonably be avoided in routine field measurements. Avoidable sources would include, but are not limited to: modifications to the sample, measurement procedure, or measurement equipment of the validated method, and gross and easily discernible transcription errors (provided there was a way to detect and either correct or eliminate them).

1.3.4Low Probability of False Detection—The IDE is a true concentration consistent with a measured concentration threshold (critical measured value) that will provide a high probability, 99 %, of true nondetection (a low probability of false detection, α = 1 %). Thus, when measuring a blank sample, the probability of not detecting the analyte would be 99 %. To be useful, this must be demonstrated for the particular matrix being used, and not just for reagent water.

1.3.5Low Probability of False Nondetection—The IDE should be a true concentration at which there is a high probability, at least 95 %, of true detection (a low probability of false nondetection, β = 5 %, at the IDE), with a simultaneous low probability of false detection (see 1.3.4). Thus, when measuring a sample at the IDE, the probability of detection would be at least 95 %. To be useful, this must be demonstrated for the particular matrix being used, and not just for reagent water.

Note 1The referenced probabilities, α and β, are key parameters for risk-based assessment of a detection limit.

1.4The IDE applies to measurement methods for which calibration error is minor relative to other sources, such as when the dominant source of variation is one of the following (with comment):

1.4.1Sample Preparation, and calibration standards do not have to go through sample preparation.

1.4.2Differences in Analysts, and analysts have little opportunity to affect calibration results (such as with automated calibration).

1.4.3Differences in Laboratories, for whatever reasons, perhaps difficult to identify and eliminate.

1.4.4Differences in Instruments(measurement equipment), which could take the form of differences in manufacturer, model, hardware, electronics, sampling rate, chemical processing rate, integration time, software algorithms, internal signal processing and thresholds, effective sample volume, and contamination level.

1.5Alternative Data Quality Objectives—Other values forα, β, confidence, etc. may be chosen for calculating an IDE; however, this procedure addresses only the 99 %/95 % IDE.

ASTM D 4128 : 2018 Standard Guide for Identification and Quantitation of Organic Compounds in Water by Combined Gas Chromatography and Electron Impact Mass Spectrometry
ASTM D 6689 : 2001 : R2019 : EDT 1 Standard Guide for Optimizing, Controlling, and Reporting Test Method Uncertainties from Multiple Workstations in the Same Laboratory Organization
ASTM D 7510 : 2010 : R2016 : EDT 1 Standard Practice for Performing Detection and Quantitation Estimation and Data Assessment Utilizing DQCALC Software, based on ASTM Practices D6091 and D6512 of Committee D19 on Water
ASTM D 7783 : 2013 Standard Practice for Within-laboratory Quantitation Estimation (WQE)
ASTM D 596 : 2001 : R2018 Standard Guide for Reporting Results of Analysis of Water
ASTM D 7782 : 2013 Standard Practice for Determination of the 99 %/95 % Critical Level (WCL) and a Reliable Detection Estimate (WDE) Based on Within-laboratory Data (Withdrawn 2022)
ASTM D 2777 : 2013 Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
ASTM D 6512 : 2007 : R2014 Standard Practice for Interlaboratory Quantitation Estimate (Withdrawn 2023)
ASTM E 2677 : 2014 Standard Test Method for Determining Limits of Detection in Explosive Trace Detectors

ASTM D 2777 : 2013 : REDLINE Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
ASTM D 2777 : 2012 Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
ASTM D 2777 : 2003 Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water
ASTM D 2777 : 2021 Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
ASTM D 2777 : 2013 Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
ASTM D 2777 : 1998 Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water
ASTM D 2777 : 2008 Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
ASTM D 2777 : 2006 Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
ASTM D 2777 : 2008 : EDT 1 Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.