ASTM D 6330 : 2020
Current
The latest, up-to-date edition.
Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Chambers Under Defined Test Conditions
Hardcopy , PDF
English
01-05-2020
Committee |
D 22
|
DocumentType |
Standard Practice
|
Pages |
10
|
ProductNote |
THIS STANDARD ALSO REFERS TO ISO 17025:2017, EPA TO-17
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
Supersedes |
1.1The practice measures the volatile organic compounds (VOC), excluding formaldehyde, emitted from manufactured wood-based panels. A pre-screening analysis is used to identify the VOCs emitted from the panel. Emission factors (that is, emission rates per unit surface area) for the VOCs of interest are then determined by measuring the concentrations in a small environmental test chamber containing a specimen. The test chamber is ventilated at a constant air change rate under the standard environmental conditions. For formaldehyde determination, see Test Method D6007.
1.2This practice describes a test method that is specific to the measurement of VOC emissions from newly manufactured individual wood-based panels, such as particleboard, plywood, and oriented strand board (OSB), for the purpose of comparing the emission characteristics of different products under the standard test condition. For general guidance on conducting small environmental chamber tests, see Guide D5116.
1.3VOC concentrations in the environmental test chamber are determined by adsorption on an appropriate single adsorbent tube or multi-adsorbent tube, followed by thermal desorption and combined gas chromatograph/mass spectrometry (GC-MS) or gas chromatograph/flame ionization detection (GC-FID). The air sampling procedure and the analytical method recommended in this practice are generally valid for the identification and quantification of VOCs with saturation vapor pressure between 500 and 0.01 kPa at 25°C, depending on the selection of adsorbent(s).
Note 1:VOCs being captured by an adsorbent tube depend on the adsorbent(s) and sampling procedure selected (see Practice D6196). The user should have a thorough understanding of the limitations of each adsorbent used. Although canisters can be used to sample VOCs, this standard is limited to sampling VOCs from the chamber air using adsorbent tubes.
1.4The emission factors determined using the above procedure describe the emission characteristics of the specimen under the standard test condition. These data can be used directly to compare the emission characteristics of different products and to estimate the emission rates up to one month after the production. They shall not be used to predict the emission rates over longer periods of time (that is, more than one month) or under different environmental conditions.
1.5Emission data from chamber tests can be used for predicting the impact of wood-based panels on the VOC concentrations in buildings by using an appropriate indoor air quality model, which is beyond the scope of this practice.
1.6The values stated in SI units shall be regarded as the standard (see IEEE/ASTM SI-10).
1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specified hazard statements see Section 6.
1.8This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D 1914 : 1995 : R2022 | Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres |
ASTM D 6007 : 2014 | Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber |
ASTM D 6196 : 2015 : EDT 1 | Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air |
ASTM D 6196 : 2023 | Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air |
ASTM E 355 : 1996 : R2021 : EDT 1 | Standard Practice for Gas Chromatography Terms and Relationships |
ASTM D 6007 : 2022 | Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber |
ASTM D 1914 : 1995 : R2014 | Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres |
ASTM E 355 : 1996 : R2014 | Standard Practice for Gas Chromatography Terms and Relationships |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.