ASTM D 7143 : 2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products
Hardcopy , PDF
11-11-2014
English
01-03-2011
Committee |
D 22
|
DocumentType |
Standard Practice
|
Pages |
20
|
ProductNote |
Reconfirmed 2011
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
Supersedes |
1.1 This practice is intended for determining volatile organic compound (VOC) emissions from materials and products using emission cells. It can be applied in principle to most construction materials and many products used indoors. Objectives include:
1.1.1 To provide manufacturers, builders, and end users with emission data useful for evaluating the impact of building products, new or old, on indoor air concentrations in a model room.
1.1.2 To promote the development of products with lower VOC emissions.
1.2 This practice is for identifying emitted VOCs and for determining the area specific emission rate of VOCs from newly produced building products under defined climate conditions. The method can also be applied to aged products.
1.3 In accordance with the definition of an emission cell, it is also possible to perform nondestructive emission measurements on building products on-site in buildings. However, the procedure for such measurements is not described in this standard.
1.4 This practice describes the design, construction, performance evaluation and use of emission cells for VOC emission testing. Sampling, transport and storage of materials to be tested, and preparation of test specimens are also described.
1.5 Air sampling and analytical methods for the determination of VOCs are described in Practice D6196. Alternative sampling and analytical approaches for formaldehyde and other carbonyls are described in Test Method D5197.
Note 1—All volatile (vapor-phase) carbonyls except formaldehyde can be analyzed by either Practice D6196 or by Test Method D5197.
Note 2—Direct-reading instruments can also be applied for specific objectives.
Note 3—Some volatile inorganic compounds can, in principle, also be analyzed (for example, ammonia).
1.6 An example of an emission cell is described in Appendix X2 of this practice.
1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
ASTM D 5116 : 2017 | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products |
ASTM D 7339 : 2018 | Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography |
ASTM D 7911 : 2014 | Standard Guide for Using Reference Material to Characterize Measurement Bias Associated with Volatile Organic Compound Emission Chamber Test |
ASTM D 7706 : 2017 | Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.